Home LiteratureArticle Details
PMID: 39632927 Published · epublish English Journal Article

Developing a nearly automated open-source pipeline for conducting computational fluid dynamics simulations in anterior brain vasculature: a feasibility study.

Scientific reports ·Vol. 14 ·No. 1 ·2024-00-04 ·页码 30181

Rezaeitaleshmahalleh M, Mu N, Lyu Z, Gemmete J, Pandey A, Jiang J

Abstract

Intracranial aneurysms (IA) pose significant health risks and are often challenging to manage. Computational fluid dynamics (CFD) simulation has emerged as a powerful tool for understanding lesion-specific hemodynamics in and around IAs, aiding in the clinical management of patients with an IA. However, the current workflow of CFD simulations is time-consuming, complex, and labor-intensive and, thus, does not fit the clinical environment. To address these challenges, we have developed a semi-automated pipeline integrating multiple open-source software packages to streamline the CFD simulation process. Specifically, the study utilized medical angiography data from 18 patients. An in-house open-source DL image segmentation model (ARU-Net) was employed to generate 3D computer models of the anterior circulation. The segmented intracranial vasculature models, including IAs, were further refined using the Vascular Modeling Toolkit (VMTK), an open-source Python package. This step involved smoothing the surface of the models and extending the inlet and outlet regions to ensure a realistic representation of the vascular geometry. The refined vascular models were then converted into computational meshes using an open-source mesh generator known as TetGen. This process was nearly automated and required minimal user interaction(s). Blood flow simulations of the cerebral vascular models were performed using established SimVascular solvers (an open-source finite element platform for vascular applications) through an application programming interface (API). The CFD simulation process was also conducted using the manual workflow for comparative purposes. The initial assessment compared the geometries derived from manual and DL-based segmentation. The DL-based segmentation demonstrated reliable performance, closely aligning with manually segmented results, evidenced by excellent Pearson correlation coefficient (PCC) values and low relative difference (RD) values ranging from 3% to 10% between the computed geometrical variables derived from both methods. The statistical analysis of the computed hemodynamic variables, including velocity informatics and WSS-related variables, indicated good to excellent reliability for most parameters (e.g., ICC of 0.85-0.95). Given the data investigated, the proposed automated workflow streamlines the process of conducting CFD simulations. It generates results consistent with the current standard manual CFD protocol while minimizing dependence on user input.

Keywords
Computational fluid dynamics Intracranial aneurysm SimVascular Velocity-informatics
MeSH 主题词
Humans Feasibility Studies Hydrodynamics Intracranial Aneurysm/physiopathology,diagnostic imaging Computer Simulation Software Hemodynamics Brain/blood supply,diagnostic imaging,physiology Cerebrovascular Circulation/physiology Models, Cardiovascular
作者与单位
共 6 位作者,点击展开单位 / ORCID
Rezaeitaleshmahalleh Mostafa
Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, USA. | Center for Biocomputing and Digital Health, Institute of Computing and Cybernetics and Health Research Institute, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, USA.
Mu Nan
Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, USA. | Center for Biocomputing and Digital Health, Institute of Computing and Cybernetics and Health Research Institute, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, USA. | Sichuan Normal University, Chengdu, Sichuan, China.
Lyu Zonghan
Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, USA. | Center for Biocomputing and Digital Health, Institute of Computing and Cybernetics and Health Research Institute, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, USA.
Gemmete Joseph
Department of Radiology, University of Michigan Medical Center, Ann Arbor, MI, USA.
Pandey Aditya
Department of Radiology, University of Michigan Medical Center, Ann Arbor, MI, USA. | Department of Neurosurgery, University of Michigan Medical Center, Ann Arbor, MI, USA.
Jiang Jingfeng
Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, USA. [email protected]. | Center for Biocomputing and Digital Health, Institute of Computing and Cybernetics and Health Research Institute, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, USA. [email protected].
Article Info
Journal
Scientific reports
Abbr.
Sci Rep
ISSN
2045-2322
Corresponding email
Published
2024-00-04
电子出版
2024-00-04
页码
30181
Language
English
Country/Region
England
NLM ID
101563288
基金资助
NIBIB NIH HHS · R01 EB029570 · United States
NIH HHS · R01-EB029570A1 · United States
American Heart Association · 23Post1022454
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]