Home LiteratureArticle Details
PMID: 40031108 Published · ppublish English

Statistical shape modelling of the left ventricle for patients with HeartMate2 and HeartMate3 ventricular assist devices.

Computers in biology and medicine ·Vol. 189 ·2025-05-00

Azimi M, Almeida DF, Khamooshi M, Liao S, Šeman M, Taylor A, McGiffin D, Gregory SD

Abstract

Left ventricular assist devices (LVADs) have demonstrated promising outcomes in the management of end-stage heart failure. However, the altered intraventricular flow dynamics following LVAD implantation can lead to non-physiological shear rates and stagnant or recirculating zones, which increase the risk of thrombosis around the inflow cannula. There are conflicting recommendations regarding the optimal inflow cannula design and its association with thrombosis risk, possibly due to anatomical variations among patients. To explore the sources of these discrepancies, statistical shape models (SSMs) of the left ventricle (LV) were utilized to numerically evaluate the impact of anatomical variations on thrombosis risk. Nineteen CT scans of LVAD patients, consisting of 5 HeartMate2 (HM2) and 14 HeartMate3 (HM3) devices, were manually segmented. The coherent point drift (CPD) algorithm was implemented to register the segmented LVs. Separate SSMs were developed for HM2 and HM3 cohorts using a principal component analysis (PCA). Multiple anatomical metrics such as LV volume, sphericity, and cross-sectional circularity were compared. A computational fluid dynamics (CFD) analysis was performed for an end-stage heart failure condition characterised by rigid LV walls, closed aortic valve and LVAD flow rate of 5 L/min. Thrombosis risk was assessed by wall shear stress (WSS), stasis volume, turbulent kinetic energy (TKE) and washout. The HM2 and HM3 cohorts exhibited differences in sphericity, apical circularity, and conicity, which may be attributed to device shape and implantation technique. For both SSMs, larger LV volume was the main anatomical feature contributing to increased stasis volume and slower blood clearance, leading to higher thrombosis risk. The second anatomical metric contributing to increased thrombosis risk was reduced LV sphericity (HM2 patients) and formation of an apical bulge (HM3 patients). This study highlighted the statistical differences in LV shape between HM2 and HM3 patients, demonstrating how specific geometrical features of the LV may predispose patients to thrombus formation after LVAD implantation.

Keywords
HM2 HM3 Inflow cannula LVAD SSM Thrombosis
MeSH 主题词
Humans Heart-Assist Devices Heart Ventricles/diagnostic imaging,physiopathology Models, Cardiovascular Male Middle Aged Female Heart Failure/physiopathology,diagnostic imaging Adult Aged Thrombosis/physiopathology Tomography, X-Ray Computed
Article Info
Journal
Computers in biology and medicine
Abbr.
Comput Biol Med
ISSN
1879-0534
Corresponding email
Published
2025-05-00
Language
English
Country/Region
United States
NLM ID
1250250
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]