Fluid-structure interaction analysis of bioinspired polymeric heart valves with experimental validation.

Liu X, Lee A, Wang Y, Hoang TP, Yee KS, Mosse L, Karajan N, Winlaw DS, Naficy S, Fletcher DF

Abstract

Valvular heart disease, when not addressed adequately, can result in heart failure, serious heart-related health problems, and in some cases, death. Polymeric heart valves (PHVs) are promising valve replacement technologies that may offer improved durability and better biological performance. Notably, PHVs have the potential to accommodate highly innovative valve designs. Given this feature of PHVs, it is important to shortlist the best performing valve designs prior to committing to extensive in vitro hemodynamic validation prototypes. This study presents a computational fluid-structure interaction (FSI) workflow, which integrates computational fluid dynamics (CFD) and finite element analysis (FEA), to simulate the hemodynamic performance of PHVs with two different valve designs under physiological conditions. The model accurately predicts cardiac output (CO), effective orifice area (EOA) and regurgitant fraction (RF) and these predictions have been successfully validated using experimental data. Consistent with experimental findings, increasing valve thickness results in a decrease in EOA, with RF trends varying between different valve designs. The fully opened and unfolded valve exhibited the lowest WSS on the leaflet surfaces. Both valve design and thickness significantly influence stress distribution along the leaflets with the thinnest valves showing lower von Mises stresses during opening and higher stresses during closing. Detailed analysis of flow patterns, wall shear stress (WSS), valve opening and closing behaviors, and mechanical stress distribution are presented. This work demonstrates the potential of FSI simulations in predicting the hydrodynamic and mechanical behavior of PHVs, offering valuable insights into valve durability and design optimization for improved patient outcomes. This approach can significantly accelerate valve development by reducing reliance on extensive in vitro and in vivo testing.

Keywords
Body-fitted method Computational fluid dynamics Fluid structure interaction Hydrodynamic performance Polymeric heart valve
MeSH 主题词
Heart Valve Prosthesis Hydrodynamics Finite Element Analysis Polymers/chemistry Prosthesis Design Hemodynamics Humans Computer Simulation Stress, Mechanical Models, Cardiovascular Heart Valves
Article Info
Journal
Computer methods and programs in biomedicine
Abbr.
Comput Methods Programs Biomed
ISSN
1872-7565
Corresponding email
Published
2025-08-00
Language
English
Country/Region
Ireland
NLM ID
8506513
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]