Home LiteratureArticle Details
PMID: 40454658 Published · ppublish English

Translation of Animal Study to Human: In Silico Based Development of Implantable Pulmonary Artery Pressure Sensor.

Goubergrits L, Yevtushenko P, Schlief A, Romberg J, Kuehne T, Arndt A, Bruening J

Abstract

Implantable pulmonary artery pressure sensors (PAPS) might impose a flow-induced risk of thrombus formation in the pulmonary artery (PA). To assess this risk, an in silico study-enhanced animal study with 20 sensors implanted in 10 pigs had previously been conducted. In the in silico study, PAPS were virtually implanted mimicking real implantations, based upon data acquired by CT. This animal in silico study investigated changes in hemodynamics caused by PAPS using image-based computational fluid dynamics (CFD). However, porcine and human PA differ significantly in geometry and hemodynamics. To investigate the transferability of animal in silico study findings toward human conditions, we propose a parallel in silico human study. Based on a similarity analysis (L1 norm for 8 geometric features) human PA geometries with the least difference to 10 porcine PA were selected. PAPS were virtually implanted in human PA as close as possible, mimicking the implantation configuration of the animal study. Finally, a numerical flow analysis of the hemodynamic changes due to PAPS implantation was done. Comparing human and porcine PA, we found significantly larger left and right PA diameters in humans, whereas no differences were found for main PA diameters and bifurcation angle. Comparing hemodynamic boundary conditions, we found a significantly smaller heart rate and a significantly higher peak systolic main PA flow rate in humans, whereas no significant differences for cardiac output were found. The human in silico PAPS study found no relevant changes in hemodynamics increasing the risk of thrombus formation after sensor implantation. This is also valid for PAPS that were non-optimally implanted. Thus, despite differences between species, findings of the in silico animal study were confirmed by the human in silico study.

Keywords
animal trial computational fluid dynamics pressure sensor pulmonary artery thrombus formation
MeSH 主题词
Pulmonary Artery Blood Pressure Translational Research, Biomedical Computer Simulation Humans Animals Swine Models, Animal Thrombosis/etiology Risk Hemodynamic Monitoring/adverse effects,instrumentation Prostheses and Implants/adverse effects Blood Pressure Determination/adverse effects,instrumentation
Article Info
Journal
International journal for numerical methods in biomedical engineering
Abbr.
Int J Numer Method Biomed Eng
ISSN
2040-7947
Published
2025-06-00
Language
English
Country/Region
England
NLM ID
101530293
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]