Home LiteratureArticle Details
PMID: 40574819 Published · epublish English Journal Article

Quantitative comparisons of pulmonary artery hemodynamics before and after Pulsta valve implantation in patients with Tetralogy of Fallot using computational fluid dynamics.

Frontiers in cardiovascular medicine ·Vol. 12 ·2025-00-00 ·页码 1586134

Baek SM, Choi K, Lee SY, Lim HG, Kim GB, Seo J

Abstract

The evaluation of percutaneous pulmonary valve implantation (PPVI) performance has been predominantly confined to assessing changes in the right ventricular volume using magnetic resonance imaging (MRI). This study aimed to evaluate the hemodynamic changes in the pulmonary arteries following PPVI using computational fluid dynamics (CFD) in patients with Tetralogy of Fallot. We conducted CFD analysis based on MRI scans performed before and after PPVI using Pulsta valve in nine patients who underwent PPVI between 2016 and 2021. Statistical analysis, including Wilcoxon rank-sum tests and multivariable linear regression, was performed to examine the associations between CFD data and non-CFD factors, as well as changes in these parameters after PPVI. Before PPVI, forward and backward flow velocities in the right pulmonary artery (RPA) were higher than those in the left pulmonary artery (LPA) and main pulmonary artery (MPA) (forward: MPA/RPA/LPA = 19.9/32.7/19.3 cm/s, backward: MPA/RPA/LPA = 10.1/17.0/9.1 cm/s). After PPVI, velocities decreased (forward: MPA/RPA/LPA = 13.3/14.2/8.3 cm/s, backward: MPA/RPA/LPA = 2.3/2.6/1.7 cm/s), reducing the differences among PAs. After PPVI, the vorticity (RPA; 3.9-1.6/s, p = 0.008, LPA; 4.4-1.8/s, p = 0.011, MPA; 5.4-1.5/s, p = 0.008), and energy dissipation (104.1-38.1 mW, p = 0.028) decreased significantly, whereas changes in the Womersley and Reynolds numbers were not statistically significant. There was no correlation between the right ventricular end-diastolic volume index and energy dissipation, and the changes in each of them were also unrelated to each other. A deeper understanding of the hemodynamics of pulmonary arteries using CFD can aid in evaluating the effectiveness of PPVI and refining its indications in patients with Tetralogy of Fallot.

Keywords
cardiac magnetic resonance imaging computational fluid dynamics percutaneous pulmonary valve implantation pulmonary regurgitation tetralogy of fallot
作者与单位
共 6 位作者,点击展开单位 / ORCID
Baek Seung Min
Department of Pediatrics, Seoul National University Children's Hospital, Seoul, Republic of Korea.
Choi Kieun
Department of Mechanical Engineering, College of Engineering, Kyung Hee University, Yongin, Gyeonggi-do, Republic of Korea.
Lee Sang Yun
Department of Pediatrics, Seoul National University Children's Hospital, Seoul, Republic of Korea.
Lim Hong Gook
Department of Thoracic and Cardiovascular Surgery, Seoul National University Children's Hospital, Seoul, Republic of Korea.
Kim Gi Beom
Department of Pediatrics, Seoul National University Children's Hospital, Seoul, Republic of Korea.
Seo Jongmin
Department of Mechanical Engineering, College of Engineering, Kyung Hee University, Yongin, Gyeonggi-do, Republic of Korea.
Article Info
Journal
Frontiers in cardiovascular medicine
Abbr.
Front Cardiovasc Med
ISSN
2297-055X
Published
2025-00-00
电子出版
2025-00-12
页码
1586134
Language
English
Country/Region
Switzerland
NLM ID
101653388
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]