Home LiteratureArticle Details
PMID: 40635601 Published · aheadofprint English Journal Article

Design and structural deformation assessment of three-dimensional printed dental implants by means of finite element analysis.

Ramirez-Fernandez O, Duran-Gonzalez I, Equihua-Guillen F, Avila LC, Camporredondo E, Garcia-Lara A, Zuñiga-Aguilar E

Abstract

BackgroundThe increasing demand for dental implants necessitates the exploration of advanced materials and manufacturing techniques. Three-dimensional (3D) printing has emerged as a viable method for producing custom dental implants, allowing for intricate designs and improved patient-specific fits. This study focuses on the design and structural deformation assessment of 3D-printed dental implants using Finite Element Analysis (FEA). By simulating the mechanical behavior of these implants under realistic loading conditions, we aim to evaluate their performance and predict potential failure points, ultimately enhancing their reliability and longevity in clinical applications.ObjectiveThe primary objective of this study is to conduct a comprehensive design and structural deformation assessment of three-dimensional (3D) printed dental implants using Finite Element Analysis (FEA). Specifically, the study aims to: Evaluate stress distribution and deformation patterns in three 3D-printed dental implant designs under simulated physiological loading.Compare the stiffness, strength, and elastic behavior of PEEK and CFR-PEEK under occlusal forces.Identify failure points in implants and bone-implant interfaces by analyzing high stress concentrations.Predict the biomechanical behavior of a novel dental implant by determining its elastic modulus through finite element analysis (FEA).MethodsThree models 3D were designed to understand stress distribution with different structures using PEEK as biomaterial, with 4 test conditions modeled and compared. An occlusal load was applied (230 N at 90˚ and 30˚) on the implants. Isotropic, linear elastic, and homogeneous were considerate as properties of the components.ResultsUnder axial loads, all models stayed within physiological stress limits, while under 30° oblique loading, Model 3 showed the lowest stress, strain, and pressure.ConclusionsFEA results indicate that 3D-printed dental implants, particularly the optimized Model 3, maintain safe stress levels under axial and oblique loads, supporting their potential for immediate loading. However, due to numerical limitations, experimental validation remains necessary to advance implant designs that optimize bone regeneration and material efficiency.

Keywords
Biomaterials computer design finite element analysis implant tooth
作者与单位
共 7 位作者,点击展开单位 / ORCID
Ramirez-Fernandez Odin ORCID
Departamento de Ingenieria Biomedica, Universidad Politécnica de Cuautitlán Izcalli, 54720, CDMX, México. | Departamento de Investigación, Universidad Tecnológica de México-UNITEC México-Campus en Línea, Col. 9 Anáhuac, Ciudad de México, 11320, CDMX, México.
Duran-Gonzalez Iliana
Departamento de Investigación, Universidad Tecnológica de México-UNITEC México-Campus en Línea, Col. 9 Anáhuac, Ciudad de México, 11320, CDMX, México.
Equihua-Guillen Fabian ORCID
Departamento de Materiales, Universidad Autónoma de Coahuila, 25750, Monclova, México.
Avila Laura Castruita ORCID
Departamento de Materiales, Universidad Autónoma de Coahuila, 25750, Monclova, México.
Camporredondo Emilio ORCID
Departamento de Materiales, Universidad Autónoma de Coahuila, 25750, Monclova, México.
Garcia-Lara Adrian ORCID
Departamento de Materiales, Universidad Autónoma de Coahuila, 25750, Monclova, México.
Zuñiga-Aguilar Esmeralda ORCID
Departamento de Ingenieria Biomedica, Universidad Autónoma de Ciudad Juárez Chihuahua, 32315, Ciudad Juarez, México.
Article Info
Journal
Technology and health care : official journal of the European Society for Engineering and Medicine
Abbr.
Technol Health Care
ISSN
1878-7401
Published
2025-07-10
电子出版
2025-00-10
页码
9287329251346282
Language
English
Country/Region
United States
NLM ID
9314590
勘误 / 撤稿关联
ExpressionOfConcernIn
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]