Home LiteratureArticle Details
PMID: 4085438 Published · ppublish English Journal Article

Potable water as a source for legionellosis.

Environmental health perspectives ·Vol. 62 ·1985-10-00 ·Pages 337-41

Fraser DW

Abstract

Several lines of evidence have been examined in attempts to implicate potable water as a source for legionellosis. Success has been mixed. The strongest evidence has been the similarity of strains recovered from patients and from potable water and the cessation of outbreaks following institution of measures to eradicate Legionella from potable water systems. Epidemiologic efforts to identify the effective mode of exposure to water (e.g. ingestion) have been remarkably unsuccessful. Although L pneumophila can clearly be acquired on occasion from potable water, the proportion of cases traceable to this source is unknown, as is the role of potable water as a source of infection by other Legionellae. Hyperchlorination, raising hot water temperatures to greater than 55 degrees C, and replacing rubber gaskets are useful methods for controlling outbreaks of legionellosis traced to potable water systems but are not yet justified as routine preventative methods in the absence of such an outbreak.

MeSH Terms
Humans Legionella/isolation & purification Legionnaires' Disease/epidemiology,etiology Pennsylvania Water Microbiology Water Supply
Authors & Affiliations
1 authors, click to expand affiliations / ORCID
Fraser D W
References (10)
10 references, click to expand
  1. Legionnaires' disease: description of an epidemic of pneumonia.
    N Engl J Med. 1977 Dec 1;297(22):1189-97 PMID: 335244
  2. Legionnaires' disease: isolation of a bacterium and demonstration of its role in other respiratory disease.
    N Engl J Med. 1977 Dec 1;297(22):1197-203 PMID: 335245
  3. Legionnaires' disease in a transplant unit: isolation of the causative agent from shower baths.
    Lancet. 1980 Jul 19;2(8186):118-21 PMID: 6105294
  4. Isolation of Legionella pneumophila from hospital shower heads.
    Ann Intern Med. 1981 Feb;94(2):195-7 PMID: 7469211
  5. Production of monoclonal antibodies to Legionella pneumophila serogroups 1 and 6.
    J Clin Microbiol. 1983 Oct;18(4):895-900 PMID: 6415102
  6. Hemodialysis fistula infections caused by Legionella pneumophila.
    Ann Intern Med. 1982 Feb;96(2):173-5 PMID: 7059065
  7. Nosocomial Legionnaires' disease caused by aerosolized tap water from respiratory devices.
    J Infect Dis. 1982 Oct;146(4):460-7 PMID: 6288805
  8. Perirectal abscess caused by Legionella pneumophila and mixed anaerobic bacteria.
    Ann Intern Med. 1983 Feb;98(2):184-5 PMID: 6824252
  9. Legionnaires' disease associated with a hospital water system: a cluster of 24 nosocomial cases.
    Ann Intern Med. 1983 Aug;99(2):172-8 PMID: 6881771
  10. Ubiquitousness of Legionella pneumophila in the water supply of a hospital with endemic Legionnaires' disease.
    N Engl J Med. 1982 Feb 25;306(8):466-8 PMID: 7057845
Article Info
Journal
Environmental health perspectives
Abbr.
Environ Health Perspect
ISSN
0091-6765
Published
1985-10-00
Pages
337-41
Language
English
Region
United States
NLM ID
0330411
PMCID
PMC1568698
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]