Home LiteratureArticle Details
PMID: 40928176 Published · aheadofprint English Journal Article

Effect of diverticulum entrance diameter on sigmoid sinus hemodynamics: a CFD and PIV experimental validation study.

Liu J, Huang S, Hu Z, Zhou F, Ma X, Gao B, Ding X

Abstract

Geometric changes in the sigmoid sinus diverticulum (SSD) can alter its hemodynamic - a primary factor contributing to pulsatile tinnitus (PT). However, not all SSD cases lead to clinical PT symptoms. This study aims to investigate the influence of the diameter of the diverticulum (EDD) on the hemodynamics of the sigmoid sinus in PT. We reconstructed CTA images from 26 PT patients. A statistical analysis of EDD, depth, and diverticulum angle, was conducted across these cases. Based on the geometric characteristics obtained, we established seven idealized models with varying EDDs and performed computational fluid dynamics simulations. Mass flow was set at the inlet, and the outlet was assigned zero pressure. We conducted Particle Image Velocimetry experiments verification. The SSD geometric models were 3D-printed using UV-curable resin material. As the EDD decreased from 11 mm to 9.65 mm, wall pressure within the SSD increased. However, further decreases in EDD from 9.65 mm to 8.3 mm resulted in a reduction in wall pressure (case1: 123.597 Pa vs. case2: 121.325 Pa vs. case3: 128.823 Pa vs. case4: 140.814 Pa vs. case5: 124.172 Pa vs. case6: 120.559 Pa vs. case7: 124.138 Pa). The pressure within the diverticulum first increased and then decreased, with the most intense vortex blood flow observed at an EDD of 9.65 mm. The EDD is a key factor influencing hemodynamic changes within the sigmoid sinus. The intermediate EDD induce more significant blood flow disturbances. This study provides theoretical insights for PT diagnosis and diverticulum morphology assessment.

Keywords
Computational fluid dynamics Entrance diameter of diverticulum Hemodynamics PIV Pulsatile tinnitus
作者与单位
共 7 位作者,点击展开单位 / ORCID
Liu Jincheng
Center for Medical Metrology, National institute of metrology, Beijing, China.
Huang Suqin
College of Chemistry and Life Science, Beijing University of Technology, Beijing, China.
Hu Zheng
Center for Medical Metrology, National institute of metrology, Beijing, China.
Zhou Feng
Center for Medical Metrology, National institute of metrology, Beijing, China.
Ma Xueran
Center for Medical Metrology, National institute of metrology, Beijing, China.
Gao Bin
College of Chemistry and Life Science, Beijing University of Technology, Beijing, China.
Ding Xiang
Center for Medical Metrology, National institute of metrology, Beijing, China.
Article Info
Journal
Computer methods in biomechanics and biomedical engineering
Abbr.
Comput Methods Biomech Biomed Engin
ISSN
1476-8259
Published
2025-09-10
电子出版
2025-00-10
页码
1-13
Language
English
Country/Region
England
NLM ID
9802899
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]