主页 文献库文献详情
PMID: 41070148 已发表 · epublish 英语

Multimodal assessment of the left ventricular ejection fraction by echocardiography, cardiac computed tomography and cardiac magnetic resonance in patients after SARS-CoV2 infection.

Frontiers in physiology ·第 16 卷 ·2025-00-00

Gać P, Wysocki A, Beck E, Poręba M, Poręba R

摘要

The aim of the study was to compare the assessment of left ventricular ejection fraction (LVEF) performed using echocardiography, cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) in patients after SARS-CoV2 infection. The study group consisted of 108 patients (54.17 ± 8.11 years, 52% women and 48% men) with a history of SARS-CoV-2 infection. In all patients, echocardiography, CCT and CMR examinations were performed based on the guidelines of scientific societies. In echocardiography, LVEF (LVEFECHO) was determined from the apical 4-chamber and 2-chamber views, with the biplane Simpson's method. In CCT, LVEF was assessed based on the contours of the left ventricular endocardium and epicardium in multiplanar reconstructions (MPR) from the multiphase of the entire cardiac cycle, which was part of the protocol of coronary computed tomography angiography performed with retrospective ECG gating with radiation dose modulation (LVEFCCT1). Additionally, in CCT, LVEF was assessed based on the left ventricular blood pool in the above reconstructions (LVEFCCT2). For the assessment of LVEF in CMR (LVEFCMR), a standard volumetric method was used using CINE sequence images in the 2-chamber projection in the long axis and in the short axis of the left ventricle. The coefficient of variation of measurements (CV) was calculated for each pair of LVEF measurements, as well as for all LVEF measurements. The mean LVEF measurement values in the study group were 59.72% ± 7.39% for LVEFECHO, 63.36% ± 9.32% for LVEFCCT1, 64.5% ± 9.79% for LVEFCCT2, and 60.84% ± 9.29% for LVEFCMR. LVEFECHO was statistically significantly lower than LVEFCCT1 and LVEFCCT2. LVEFCMR was also statistically significantly lower than LVEFCCT1 and LVEFCCT2. CV for all LVEF measurements was 4.61% ± 1.73%. When comparing pairs of LVEF measurements, the lowest CV was observed for LVEFCCT1 and LVEFCCT2 (2.97% ± 2.64%), while the highest CV was observed for LVEFECHO and LVEFCCT2 (6.04% ± 3.39%). When comparing LVEF to the gold standard of assessment, i.e., LVEFCMR, the most consistent measurements were obtained for LVEFECHO (CV 3.00% ± 2.01%), while the least consistent measurements were obtained for CCT2 (4.65% ± 3.24%). A positive correlation was found between body mass index and CV of LVEF measurements (r = 0.44, p < 0.05), as well as between heart rate (during CCT) and CV of LVEF measurements (r = 0.37, p < 0.05). Furthermore, a negative correlation existed between LVEF measured by ECHO and CV of LVEF measurements in this group of patients (r = - 0.27, p < 0.05). There are statistically significant differences in left ventricular ejection fraction measurements in patients with a history of SARS-CoV-2 infection using different cardiac imaging modalities. Cardiac computed tomography overestimates LVEF compared to echocardiography and cardiac magnetic resonance imaging. Patients with abnormal body mass, suboptimal heart rate and reduced left ventricular systolic function are subgroups with increased variability of LVEF measurements in different cardiac imaging modalities.

关键词
SARS-CoV2 infection cardiac computed tomography cardiac magnetic resonance echocardiography left ventricular ejection fraction
文献信息
期刊
Frontiers in physiology
期刊简称
Front Physiol
ISSN
1664-042X
发表日期
2025-00-00
语言
英语
国家/地区
Switzerland
NLM ID
101549006
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]