PMID: 41222090 Published · ppublish English Journal Article Comparative Study

Comparison of thyrotropin concentrations measured by bulk acoustic wave technology and chemiluminescence in hyperthyroid cats and cats with non-thyroidal illness.

Journal of feline medicine and surgery ·Vol. 28 ·No. 1 ·2026-01-00 ·页码 1098612X251398915

Brassard C, DeMonaco SM, Wilkinson AR, Keebaugh AE, Bolton TA

Abstract

ObjectivesA thyrotropin (also known as thyroid-stimulating hormone [TSH]) assay using bulk acoustic wave (TSH-BAW) technology is a sensitive and specific test for diagnosing hyperthyroidism; however, the effect of various types of non-thyroidal illness (NTI) have not been evaluated with this assay. The objectives of this study were to compare serum TSH concentrations using the TSH-BAW and a currently available TSH chemiluminescent immunoassay (TSH-CLIA) in hyperthyroid cats, cats with NTI and healthy cats, as well as to compare sensitivity and specificity for diagnosing hyperthyroidism.MethodsA prospective cross-sectional study was conducted comparing the TSH concentration of 37 hyperthyroid, 32 healthy and 32 NTI cats using the TSH-CLIA and TSH-BAW assays. The effect of disease severity was evaluated with hyperthyroidism and NTI.ResultsThe TSH-BAW had a lower sensitivity (78%, 95% confidence interval [CI] 62-90) and negative predictive value (89%, 95% CI 79-95) but higher specificity (97%, 95% CI 89-100) and positive predictive value (94%, 95% CI 79-99) than the TSH-CLIA. The median serum TSH concentration was significantly different between hyperthyroid cats and both healthy and NTI cats with both assays (P <0.01) but was not different between NTI and healthy cats (TSH-CLIA P = 0.168, TSH-BAW P = 0.673). Eight (21.6%) hyperthyroid cats had a detectable TSH-BAW but undetectable TSH-CLIA concentration, with seven (18.9%) having a TSH-BAW within the reference interval. A total of 12 (18.8%) non-hyperthyroid cats (four [12.5%] healthy cats and eight [25%] NTI cats) had an undetectable TSH-CLIA compared with only two (6%) cats (one [3%] healthy cat and one [3%] NTI cat) with the TSH-BAW assay. The proportion of cats with an undetectable serum TSH concentration was significantly higher with the TSH-CLIA than the TSH-BAW in NTI cats (P = 0.008). This was especially evident in NTI cats suffering from moderate to severe illnesses (P = 0.025).Conclusions and relevanceThe TSH-BAW has a high specificity for detecting hyperthyroidism and identifies a normal serum TSH concentration in non-hyperthyroid cats more often than the TSH-CLIA. However, a normal result cannot be used to rule out hyperthyroidism.

Keywords
BAW Feline thyrotropin bulk acoustic wave feline thyroid-stimulating hormone hyperthyroidism
MeSH 主题词
Animals Cats Cat Diseases/blood,diagnosis Hyperthyroidism/veterinary,blood,diagnosis Female Male Thyrotropin/blood Prospective Studies Cross-Sectional Studies Sensitivity and Specificity Luminescent Measurements/veterinary,methods
化学物质
Thyrotropin
作者与单位
共 5 位作者,点击展开单位 / ORCID
Brassard Camille ORCID
Small Animal Internal Medicine Service, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA, USA. | Internal Medicine Department, MedVet Silicon Valley, San Jose, CA, USA.
DeMonaco Stefanie M ORCID
Small Animal Internal Medicine Service, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA, USA.
Wilkinson Ashley R
Small Animal Internal Medicine Service, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA, USA.
Keebaugh Audrey E ORCID
Small Animal Internal Medicine Service, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA, USA.
Bolton Timothy A ORCID
Small Animal Internal Medicine Service, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA, USA. | Small Animal Internal Medicine Service, Purdue University College of Veterinary Medicine, West Lafayette, IN, USA.
Article Info
Journal
Journal of feline medicine and surgery
Abbr.
J Feline Med Surg
ISSN
1532-2750
Published
2026-01-00
电子出版
2025-00-12
页码
1098612X251398915
Language
English
Country/Region
England
NLM ID
100897329
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]