Home LiteratureArticle Details
PMID: 41346491 Published · epublish English

CT predicts intraprocedural hemodynamics with computational fluid dynamics in TMVR-ineligible patients undergoing M-TEER.

Frontiers in cardiovascular medicine ·Vol. 12 ·2025-00-00

Kirchner J, Gerçek M, Omran H, Kassar M, Gräni C, Praz F, Rudolph F, Rudolph V, Rudolph TK

Abstract

Hemodynamic outcomes in patients undergoing transcatheter mitral edge-to-edge repair (M-TEER) are difficult to predict. Computational fluid dynamics (CFD) is frequently used in biomedical engineering to simulate blood flow patterns under various conditions. We developed a standardized workflow for individualized CFD analyses to predict postinterventional mitral valve gradients and residual regurgitation following TEER. Twenty patients with severe mitral regurgitation (MR) from two high-volume centers underwent full-cycle cardiac computed tomography before intervention. Based on the specific valve morphology, individualized CFD simulations were performed to calculate MR volumes prior to intervention and estimate hemodynamics after M-TEER. CFD analyses (mean age 80 ± 4 years, 55% male) showed excellent correlation between baseline proximal isovelocity surface area (PISA)-based MR volumes, median 40 ml [interquartile range (IQR): 30-49 ml], and CFD-based calculation, median 30 ml (IQR: 27-54 ml; R = 0.917; P < 0.001), as well as between baseline effective regurgitant orifice area (EROA) assessed in transesophageal echocardiography (TEE) and CFD-measured EROA (R = 0.869; P < 0.001). After device implantation, the correlation between intraprocedural TEE-measured and CFD-estimated residual MR (R = 0.949; P < 0.001) and EROA (R = 0.841; P < 0.001) remained robust. Median postinterventional diastolic pressure gradient (TEE) was 2.8 mmHg (IQR: 1.7-4.0), which closely correlated with the CFD-estimated gradient of 1.4 mmHg (IQR: 2.3-4.5, R = 0.905; P < 0.001). This is the first study to use a standardized CFD workflow for MR evaluation in patients undergoing TEER. In the future, CFD-based analyses may serve as a key diagnostic tool for procedural planning of TEER.

Keywords
CT computational fluid dynamics hemodynamic mitral regurgitation transcatheter edge-to-edge repair
Article Info
Journal
Frontiers in cardiovascular medicine
Abbr.
Front Cardiovasc Med
ISSN
2297-055X
Published
2025-00-00
Language
English
Country/Region
Switzerland
NLM ID
101653388
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]