主页 文献库文献详情
PMID: 41598803 已发表 · epublish 英语

Algorithm for Reporting Free Hemoglobin in ECMO Patients: Need for a Multidisciplinary Approach.

Journal of clinical medicine ·第 15 卷 ·第 2 期 ·2026-01-21

Baršić Lapić I, Zaninović L, Lovrić D, Lončar Vrančić A, Rebrek D, Rogić D

摘要

Background: Intravascular hemolysis is a common complication in patients undergoing extracorporeal membrane oxygenation (ECMO), with plasma free hemoglobin (pfHb) serving as a biomarker for detection. Without standardized protocols, laboratories face challenges in interpreting and reporting results. Hemolysis indices may enhance reporting accuracy. Methods: This retrospective observational study at University Hospital Center Zagreb included 61 lithium heparin plasma samples from ECMO patients. pfHb was measured using the Harboe method (fHb) and estimated from hemolysis indices on Abbott Alinity c analyzer (efHb). Total and conjugated bilirubin, hemolysis, icterus, and lipemia indices (HIL) were recorded. Method comparison used Passing-Bablok regression and Bland-Altman analysis. An algorithm for pfHb reporting accounting for HIL interferences was developed. Results: Significant differences were observed between methods, with Harboe yielding higher median fHb (261 mg/L) versus efHb (58 mg/L). Regression analysis showed constant negative bias of -91 mg/L (95% CI: -143 to -16) for efHb relative to fHb. Bland-Altman analysis demonstrated wide limits of agreement. Correlation between fHb and efHb was moderate (Spearman's rho = 0.618, p < 0.001). The delta between methods increased with higher bilirubin concentrations. An algorithm integrating HIL indices with the Harboe method was developed to guide result validation and reporting. Conclusions: Accurate hemolysis assessment in ECMO patients requires careful interpretation, appropriate method selection, and laboratory-clinician collaboration. The proposed algorithm improves the clinical utility of pfHb testing by accounting for analytical interferences and supporting informed decision-making.

关键词
ECMO algorithm hemolysis index icteria plasma free hemoglobin
文献信息
期刊
Journal of clinical medicine
期刊简称
J Clin Med
ISSN
2077-0383
发表日期
2026-01-21
语言
英语
国家/地区
Switzerland
NLM ID
101606588
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]