主页 文献库文献详情
PMID: 41645028 已发表 · ppublish 英语

MoCo + ROVir: Synergy Between Respiratory Motion Compensation and Cardiac Receive Region Focusing for Cardiac MRI.

Magnetic resonance in medicine ·第 95 卷 ·第 6 期 ·2026-06-00

Hu Z, Lee HL, Cao T, Yoshida T, Ma L, Finn JP, Nguyen KL, Christodoulou AG

摘要

To improve cardiac motion representation and reduce artifacts for cardiac- and respiratory-resolved imaging through a synergistic combination of retrospective cardiac phased array RF focusing and rigid respiratory motion compensation (MoCo). We incorporated cardiac receive focusing using region-optimized virtual coils (ROVir) and MoCo into cardiac- and respiratory-resolved low-rank tensor (LRT) reconstruction, hypothesizing that the combination of MoCo + ROVir would prioritize the LRT representation of cardiac motion over respiratory motion. We compared LRT, MoCo-LRT, ROVir-LRT, and the proposed MoCo + ROVir-LRT reconstructions of retrospective data from N = 24 pediatric patients with congenital heart disease (CHD) scanned at 3.0 T using ROCK-MUSIC. Technical evaluation metrics included the proportion of cardiac-to-respiratory motion energy in self-gating lines, cardiac motion priority in the temporal basis, flickering energy, and edge sharpness in end-expiratory cardiac cine. Reconstructed cardiac cines were scored by two expert image readers. MoCo + ROVir significantly increased the proportion of cardiac-to-respiratory motion energy in self-gating lines (p < 0.001) and prioritized cardiac motion in the temporal basis (p < 0.001). MoCo + ROVir reduced flickering energy in cardiac cine images (p < 0.001), sharpened the liver-lung interface (p < 0.001), and improved flickering-specific scores (p = 0.001). Myocardium-blood pool interface sharpness (p = 0.831), cardiac-specific image scores (p = 0.188), and vascular-specific scores (p = 0.901) were not significantly different. Together, these two techniques allowed 3.7-5.2× faster reconstruction times versus LRT-only. The synergy of MoCo + ROVir successfully prioritized cardiac motion, suppressed respiratory motion, and reduced flickering artifacts, with an added benefit of accelerating reconstruction times. The improved respiratory motion handling may provide an avenue for free-breathing cardiac scans in pediatric patients with CHD.

关键词
cardiac MRI congenital heart disease low‐rank tensor multichannel MRI pediatric MRI signal suppression
文献信息
期刊
Magnetic resonance in medicine
期刊简称
Magn Reson Med
ISSN
1522-2594
发表日期
2026-06-00
语言
英语
国家/地区
United States
NLM ID
8505245
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]