Home LiteratureArticle Details
PMID: 41723959 Published · ppublish English

Egg-level temperature monitoring and CFD-guided structural optimization improve thermal uniformity and hatch performance in a single-stage tunnel incubator.

Poultry science ·Vol. 105 ·No. 5 ·2026-05-00

Li M, Shi Z, Bai Z, Hu Y, Han G

Abstract

Temperature uniformity inside commercial tunnel incubators is critical for hatchability and chick quality, but quantitative field data and validated engineering solutions remain limited. This study combined in situ EST measurements, hatch performance evaluation and computational fluid dynamics (CFD) modeling to characterize and improve the thermal environment in a single-stage tunnel incubator. In one tunnel incubator (capacity 90,720 eggs; operated under standard single-stage conditions), eggshell temperature (EST) was monitored at 15 locations (5 trolleys × 3 vertical tiers; 1-min logging for 12 h on embryonic day 1) during half-capacity (37,800 eggs) loading. Hatchability, hatch time, and chick weight uniformity were evaluated by tier using 5 replicate hatches, with trolley-within-tier as the experimental unit. A porous-medium CFD model was validated against the 15-point EST dataset and used to test transverse trolley orientation and a perforated flow-straightening plate. Under baseline conditions, maximum intra-trolley temperature differences reached 0.84°C and trolley-level non-uniformity indices approached 0.62±0.33%. Eggs on the middle tier, which experienced warmer and more stable temperatures, showed higher hatchability (p < 0.05), earlier mean hatch time (p < 0.05) and greater chick weight uniformity (p < 0.05) than upper and lower tiers. The CFD model reproduced measured temperatures with a maximum absolute deviation of 0.35°C and predicted that transverse trolley orientation could reduce non-uniformity indices to 0.29±0.12%, while the perforated plate reduced them to 0.38±0.14%. Field implementation of transverse trolley orientation confirmed improved temperature uniformity. These findings demonstrate that egg-level monitoring combined with CFD-guided structural optimization can substantially improve the thermal environment in commercial tunnel incubators and support more uniform broiler chick production.

Keywords
Chick quality Computational fluid dynamics Eggshell temperature Porous-medium model Tunnel incubator
Article Info
Journal
Poultry science
Abbr.
Poult Sci
ISSN
1525-3171
Corresponding email
Published
2026-05-00
Language
English
Country/Region
England
NLM ID
0401150
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]