Home LiteratureArticle Details
PMID: 41891379 Published · ppublish English

Benchmarking Hybrid CNN-Transformer Versus Pure Transformer Architectures for Accelerated Hyperpolarized 129Xe MRI Reconstruction.

Journal of magnetic resonance imaging : JMRI ·Vol. 64 ·No. 1 ·2026-07-00

Babaeipour R, Fox MS, Parraga G, Ouriadov A

Abstract

Hyperpolarized 129Xe MRI faces technical challenges including low signal-to-noise ratio and breath-hold constraints. Current literature focuses on proprietary deep learning methods or image-domain enhancements. To present a comprehensive evaluation of transformer and hybrid CNN-transformer architectures integrating dual-domain (k-space and image) processing for HP 129Xe MRI reconstruction. Retrospective. Two hundred five participants (22 healthy [male and female, 18-85 years], 26 COPD [male and female, 50-85 years], 90 asthma [male and female, 18-70 years], 67 long-COVID [male and female, 18-70 years]) yielding 1640 2D slices. Dataset split: 80% training (1312 slices), 10% validation (164 slices), 10% test (164 slices). 3 T; 3D fast gradient-recalled echo. Five architectures were compared: KTMR (hybrid transformer-CNN), KIKI-net (pure CNN), ReconFormer, SwinMR, and MR-IPT (pure transformer) at acceleration factors of 3, 7, and 10. Performance was assessed using peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), and normalized mean squared error (NMSE). Ventilation defect percentage (VDP) agreement with semi-automated analysis was evaluated. Friedman test with post hoc Dunn's test and Benjamini-Hochberg correction for multiple comparisons. Significance level: p < 0.05. At 10-fold acceleration, KTMR produced PSNR of 36.4 ± 2.8 dB and SSIM of 0.88 ± 0.12, significantly outperforming KIKI-net (32.5 ± 3.4 dB, 0.81 ± 0.12), ReconFormer (29.7 ± 2.6 dB, 0.76 ± 0.12), SwinMR (30.5 ± 2.8 dB, 0.76 ± 0.09), and MR-IPT (28.8 ± 2.4 dB, 0.74 ± 0.11). VDP measurements showed mean bias of 1.94% at 3-fold, 2.12% at 7-fold, and 2.69% at 10-fold acceleration. KTMR demonstrated superior performance for HP 129Xe MRI reconstruction at high acceleration factors. 3. Stage 1.

Keywords
COPD MRI reconstruction Vision Transformers asthma deep learning hyperpolarized 129Xe MRI long‐COVID lung imaging medical imaging pulmonary imaging
Article Info
Journal
Journal of magnetic resonance imaging : JMRI
Abbr.
J Magn Reson Imaging
ISSN
1522-2586
Published
2026-07-00
Language
English
Country/Region
United States
NLM ID
9105850
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]