主页 文献库文献详情
PMID: 41946880 已发表 · epublish 英语

Development of a novel external fixation device for inducing knee arthrofibrosis in rats.

Scientific reports ·第 16 卷 ·第 1 期 ·2026-04-07

Jia J, Li W, Pan Y

摘要

Arthrofibrosis (AF) is a common pathological condition characterized by joint dysfunction. However, traditional non-invasive external fixation methods are difficult to maintain on the small limbs of rats. This study aimed to develop a novel, non-invasive, and stable rat model of knee arthrofibrosis using a thermoplastic polymer resin. Sixty male Sprague-Dawley rats were randomly assigned into a Sham group and immobilization groups (1, 2, 4, and 6 weeks). Utilizing the material's property of being malleable at high temperatures and rigid at room temperature, a custom-fitted "thigh-crus-trunk" external fixation device was fabricated to immobilize the knee at 135° of flexion. Total, arthrogenic, and myogenic contractures were assessed by measuring the range of motion (ROM). Histopathological changes were evaluated using H&E and Masson's trichrome staining. The expression of fibrotic markers (α-smooth muscle actin, α-SMA and collagen type I alpha 1 chain, COL1A1) in synovial tissues was detected via immunohistochemistry, RT-qPCR, and Western blotting. Biosafety was assessed through histological and serum biochemical analyses of major organs. Prolonged immobilization resulted in a significant decrease in knee ROM, while joint capsule thickness, synovial hyperplasia, and collagen deposition increased, stabilizing after 4 weeks. Analysis revealed that myogenic contracture predominated in the first 2 weeks, whereas arthrogenic contracture became dominant in the later stage. Molecular analysis confirmed a time-dependent upregulation of α-SMA and COL1A1 in synovial tissues. Furthermore, no abnormalities were observed in major organs or serum biochemical indices, indicating favorable biosafety. A novel non-invasive rat model of knee arthrofibrosis was successfully established using thermoplastic polymer resin. This device is cost-effective, user-friendly, stable, and biocompatible. It effectively simulates immobilization-induced joint contracture without surgical trauma, serving as a valuable model for future arthrofibrosis research.

关键词
Animal model Arthrofibrosis External fixation Rat Thermoplastic polymer resin
文献信息
期刊
Scientific reports
期刊简称
Sci Rep
ISSN
2045-2322
发表日期
2026-04-07
语言
英语
国家/地区
England
NLM ID
101563288
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]