主页 文献库文献详情
PMID: 41984260 已发表 · epublish 英语

Efficacy and safety of mesh reinforced cruroplasty with Phasix™ ST vs. Bio-A®: systematic review and bayesian meta-analysis.

Hernia : the journal of hernias and abdominal wall surgery ·第 30 卷 ·第 1 期 ·2026-04-15

Manara M, Bona D, De Bernardi S, Cavalli M, Wang Q, Bonitta G, Guido D, Biondi A, Campanelli G, Bonavina L, Aiolfi A

摘要

PURPOSE: Recurrence remains a major challenge after minimally invasive hiatus hernia (HH) repair, particularly in patients with large diaphragmatic defects. Currently, biosynthetic absorbable meshes such as Bio-A® and Phasix™ ST are widely used to reinforce cruroplasty, however evidence comparing their efficacy and safety profile remains limited. This study aims to compare the safety and efficacy of Bio-A® versus Phasix™ ST after minimally invasive HH repair through a Bayesian meta-analysis. METHODS: Systematic search across online databases up to November 2025 was performed. Inclusion criteria targeted elective minimally invasive HH repairs with Bio-A® or Phasix™ ST mesh. Primary outcome was radiologically or endoscopically confirmed anatomical HH recurrence. Overall, severe (Clavien-Dindo ≥ 3), mesh-related complications and reoperation for recurrence were secondary outcomes. A Bayesian hierarchical power prior model was utilised to pool data from both comparative and single-arm studies. RESULTS: Twenty-one observational studies (2208 patients) were included. Bio-A® was used in 53.1% of cases. The overall recurrence rate was 8.2% (n = 170 patients), with a clinical trend toward higher recurrence for Bio-A® vs. Phasix™ ST mesh (10% vs. 6%). The Bayesian meta-analysis showed no statistically significant difference for Bio-A® vs. Phasix™ ST (RR = 1.29, 95% HPD 0.01–8.15). Notably, 38 over 170 patients (17%) required reoperation for HH recurrence with a trend toward higher rates for Bio-A® vs. PhasixTM (36.3% vs. 19.3%). Overall (RR = 1.16, 95% HPD 0.01–8.75) and severe postoperative complications (RR = 1.06, 95% HPD 0.01–12.33) were comparable. Mesh-related complication with esophageal fibrosis occurred in one Bio-A® patient (0.04%). CONCLUSION: Bio-A® and Phasix™ ST synthetic absorbable meshes seem safe and effective for hiatal reinforcement with apparently similar rates of recurrence and postoperative morbidity. The choice between these materials should be guided by surgeon preferences and cost-effectiveness.

关键词
Bayesian meta-analysis Bio-A Hiatal hernia Mesh repair Phasix ST Recurrence
文献信息
期刊
Hernia : the journal of hernias and abdominal wall surgery
期刊简称
Hernia
ISSN
1248-9204
发表日期
2026-04-15
语言
英语
国家/地区
France
NLM ID
9715168
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]