Accuracy of Measuring Blood Pressure with a Volume Clamp-Based Finger Cuff vs. Arterial Line at Rest and During Exercise in Patients with Pulmonary Hypertension: A Post Hoc Analysis.

Journal of clinical medicine ·第 15 卷 ·第 8 期 ·2026-04-16

Titz A, Müller J, Schneider SR, Saxer S, Schwarz EI, Lichtblau M, Ulrich S

摘要

Background/Objective: Continuous blood pressure (BP) monitoring is essential in clinical settings, where rapid hemodynamic changes influence patient management. While intra-arterial measurement remains the reference standard, non-invasive volume-clamp systems offer a potential alternative. We assessed the accuracy of finger-cuff-based continuous BP monitoring compared to invasive measurement in patients with pulmonary hypertension (PH). Methods: This post hoc analysis from a crossover RCT included PH patients who underwent repetitive hemodynamic assessments at rest and during exercise. The participants had simultaneous invasive BP monitoring via the radial artery and a non-invasive finger-cuff device (Finapres® NOVA Basic). The mean blood pressure (mBP) was compared at rest, 50% of the maximal workload, and at the end of exercise using Bland-Altman and Taffé analysis. Results: In the study, 24 patients (seven female; 59 ± 14 years) contributed 385 paired mBP measurements. The invasive and non-invasive methods showed similar values at rest (96.1 ± 16.7 vs. 96.4 ± 17.2 mmHg) and during maximal exercise (106.8 ± 18.6 vs. 111.8 ± 21.6 mmHg). The overall Bland-Altman bias was 2.8 mmHg with wide limits of agreement (-39.6 to 45.3 mmHg), which remained broad across all exercise intensities. The Taffé analysis revealed a non-uniform, directionally dependent bias: the non-invasive system overestimated the mBP at low pressures and underestimated it at higher pressures. The measurement variability was substantially greater for the non-invasive method than for the invasive reference. Conclusions: In PH patients, finger-cuff-based continuous BP monitoring demonstrated acceptable group-level agreement but insufficient individual-level accuracy for clinical decision-making.

关键词
Bland–Altman Finapres Taffé method continuous blood pressure measurement exercise finger cuff pulmonary hypertension volume-clamp method
文献信息
期刊
Journal of clinical medicine
期刊简称
J Clin Med
ISSN
2077-0383
发表日期
2026-04-16
语言
英语
国家/地区
Switzerland
NLM ID
101606588
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]