Home LiteratureArticle Details
PMID: 42188233 Published · epublish English

Computed Fluid Dynamics-Based Blood Pressure Prediction for Coronary Artery Disease Diagnosis Using Coronary Computed Tomography Angiography.

Journal of imaging ·Vol. 12 ·No. 5 ·2026-05-02

Lisasi R, Huang H, Pei W, Esposito M, Zhao C

Abstract

Computational fluid dynamics (CFD)-based simulation of coronary blood flow provides valuable hemodynamic markers, such as pressure gradients, for diagnosing coronary artery disease (CAD). However, CFD is computationally expensive, time-consuming, and difficult to integrate into large-scale clinical workflows. These limitations restrict the availability of labeled hemodynamic data for training AI models and hinder the broad adoption of non-invasive, physiology-based CAD assessment. To address these challenges, we develop an end-to-end pipeline that automates coronary geometry extraction from coronary computed tomography angiography (CCTA), streamlines simulation data generation, and enables efficient learning of coronary blood pressure distributions. The pipeline reduces the manual burden associated with traditional CFD workflows while producing consistent training data. Furthermore, we introduce a diffusion-based regression model. Specifically, the inverted conditional diffusion (ICD) model is designed to predict coronary blood pressure directly from CCTA-derived features, thereby bypassing the need for computationally intensive CFD during inference. The proposed model is trained and validated on two CCTA datasets using the Adam optimizer with a weight decay of 1×10-3, a learning rate of 1×10-5, a batch size of 100, and Huber loss. It is then evaluated on a test set of ten simulated coronary hemodynamic cases. Experimental results demonstrate state-of-the-art performance. Compared with Long Short-Term Memory (LSTM), the proposed model improves the R2 score by 19.78%, reduces the root mean squared error (RMSE) by 19.44%, and lowers the normalized root mean squared error (NRMSE) by 18%. Compared with a multilayer perceptron (MLP), it improves the R2 score by 8.38%, reduces RMSE by 4.3%, and reduces NRMSE by 5.4%. This work represents a first step toward a scalable and accessible framework for rapid, non-invasive, CFD-based blood pressure prediction, with the potential to support CAD diagnosis.

Keywords
blood pressure prediction coronary artery disease coronary computed tomography angiography diffusion inverted conditional diffusion
Article Info
Journal
Journal of imaging
Abbr.
J Imaging
ISSN
2313-433X
Published
2026-05-02
Language
English
Country/Region
Switzerland
NLM ID
101698819
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]