Home LiteratureArticle Details
PMID: 42229834 Published · ppublish English

Proximal policy optimisation based black-box optimizer for tailoring inhalation instructions of an inhaler for minimising mouth-throat deposition.

International journal of pharmaceutics ·Vol. 700 ·2026-07-10

Ling Y, Lee A, Dong J, Kourmatzis A, Cheng S

Abstract

Inhalation therapy using dry-powder inhalers (DPIs) offers targeted drug delivery for asthma and chronic obstructive pulmonary disease (COPD). Variation in deposition rate in the mouth-throat region depends on patient inhalation manoeuvres and techniques. The present study aimed to identify optimal combinations of head position, oral opening size, and mouthpiece insertion depth for three representative inhalation manoeuvres, corresponding to low, medium and high peak inspiratory flow rates (PIFRs). An idealised adult airway model was reconstructed and coupled with transient computational fluid dynamics (CFD) simulations that incorporated the Aerolizer® mouthpiece geometry, and inhaler resistance. A proximal policy optimisation (PPO) based black-box optimizer (BO) used deposition rate in mouth-throat (DEthroat) as the reward signal to guide optimisation toward minimisation of mouth-throat deposition in the Alberta Idealised Throat (AIT) model. Key findings indicate that optimised technique adjustments can markedly reduce mouth-throat deposition. For the low PIFR case, total DEthroat decreased from (28.82 ± 0.39) % in the original geometry to (5.11 ± 0.11) %. For the medium and high peak flow cases, average absolute reductions of 23.40 and 21.02 percentage points were achieved, respectively. Optimal actions across the three manoeuvres involved extending the head upward by 8.60°-13.21°, rotating left or right by 15.18°-21.9°, widening the oral opening to a three-finger width, and inserting the mouthpiece deeper by 7.99 mm-11.82 mm, based on the AIT model. These model-based findings suggest that head position and mouth-opening adjustments may influence aerosol transport and deposition patterns. The findings are hypothesis-generating and require validation in heterogeneous, subject-specific airway anatomies before clinical applicability can be inferred.

Keywords
Computational fluid dynamics Inhalation therapy Inhaled drug delivery Proximal policy optimisation
Article Info
Journal
International journal of pharmaceutics
Abbr.
Int J Pharm
ISSN
1873-3476
Published
2026-07-10
Language
English
Country/Region
Netherlands
NLM ID
7804127
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]