Safety and Feasibility of Low-Intensity Transcranial Focused Ultrasound Targeting the Anterior Thalamus: A Pilot Study for Chronic Central Neuropathic Pain.

The journal of ECT ·2026-06-03

Aline Nunes G, Reis Ortiz J, Mingrone C, Arnaut D, Picarelli H, Ferrareto Iglesio R, de Carvalho Nogueira R, da Silva Simões J, Nascimento Martins P, Felix Bauab JR, Montes Garcia Barbosa R, Taricani Kubota G, Gisbert Cury R, Jacobsen Teixeira M, Marcolin MA

摘要

Low-intensity transcranial focused ultrasound (tFUS) is a novel noninvasive neuromodulation technique capable of reaching deep brain structures with high spatial precision. The anterior thalamus, a key relay in pain processing, is a promising target for modulating central pain networks. In this context, this study aims to assess the safety, feasibility, and preliminary effects of anterior thalamic low-intensity tFUS in patients with chronic Central Neuropathic Pain (CNP). In this prospective, open-label, single-arm pilot study, 5 adults with refractory central neuropathic pain underwent neuronavigated low-intensity transcranial focused ultrasound targeting the anterior thalamus contralateral to the pain-affected region. Each session consisted of two 10-minute stimulation blocks separated by 20 minutes. Pain intensity was assessed using the visual analog scale at baseline, immediately poststimulation, and also after 4 hours, 24 hours and 10 days after the intervention. Secondary outcomes included the Brief Pain Inventory, McGill Pain Questionnaire, Douleur Neuropatique 4, Hamilton Depression Rating Scale, Hamilton Anxiety Rating Scale, Patient Global Impression of Change and Clinical Global Impression of Change scale. The procedure demonstrated feasible with no serious adverse events. One participant experienced mild transient neck discomfort. No statistically significant improvements were observed in pain intensity or secondary outcomes at any time point compared with baseline. Overall, anterior thalamic low-intensity tFUS presented safe and feasible for patients with CNP but did not yield significant short-term analgesic effects. These findings support further controlled clinical trials with larger samples, optimized stimulation parameters and repeated sessions to better evaluate the therapeutic potential of low-intensity tFUS for chronic CNP.

关键词
anterior thalamus chronic pain focused ultrasound safety
文献信息
期刊
The journal of ECT
期刊简称
J ECT
ISSN
1533-4112
发表日期
2026-06-03
语言
英语
国家/地区
United States
NLM ID
9808943
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]