Home LiteratureArticle Details
PMID: 5573368 Published · ppublish English Journal Article

Blood flow, slip, and viscometry.

Biophysical journal ·Vol. 11 ·No. 3 ·1971-03-00 ·Pages 252-64

Nubar Y

Abstract

The viscosity of blood, measured by the usual viscometers in which slip is not considered, is found to be flow dependent, varying markedly with shear rate, pressure gradient, and vessel diameter in the lower ranges of these factors. The study postulates, on grounds thought reasonable, that slip may be present in blood flow, as a function of the nature of the wall surfaces, shear stress at the wall, and relative cell volume (RCV) adjacent to the wall. It presumes that blood possesses a specific, flow-independent viscosity, and determines theoretically the viscosity indications of viscometers if blood slipped in the instruments. The study shows that if the slip function is of a certain plausible form, these viscosity indications would exhibit a flow dependence of much the same pattern as the actual indications supplied by the usual viscometers. The slip postulate permits, therefore, an interpretation of the "anomalous" flow behavior of blood, dispensing with the prevailing assumption of an ad hoc variability of its viscosity with flow factors. To the extent that viscometric data for blood may be representative of other non-newtonian fluids, the slip postulate may be applicable to these fluids.

MeSH Terms
Biomechanical Phenomena Blood Flow Velocity Mathematics Pressure Viscosity
Authors & Affiliations
1 authors, click to expand affiliations / ORCID
Nubar Y
References (11)
11 references, click to expand
  1. Shear rate dependence of the viscosity of whole bllod and plasma.
    Science. 1961 Mar 17;133(3455):763-4 PMID: 13784262
  2. Effects of hematocrit and plasma proteins on human blood rheology at low shear rates.
    J Appl Physiol. 1966 Jan;21(1):81-7 PMID: 5903948
  3. High-speed microcinematographic studies of blood flow in vitro.
    Science. 1962 Nov 30;138(3544):981-3 PMID: 14016698
  4. Blood viscosity: influence of erythrocyte aggregation.
    Science. 1967 Aug 18;157(3790):829-31 PMID: 17842794
  5. Physical basis of the dependence of blood viscosity on tube radius.
    Am J Physiol. 1960 Jun;198:1193-200 PMID: 14400362
  6. Discrepancy in measuring blood in couette, cone and plate, and capillary tube viscometers.
    J Appl Physiol. 1968 Dec;25(6):786-9 PMID: 5727210
  7. Theory of the flow of blood in narrow tubes.
    J Appl Physiol. 1958 Jan;12(1):105-13 PMID: 13502266
  8. Effect of slip on the rheology of a composite fluid: application to blood.
    Biorheology. 1967 Sep;4(4):133-50 PMID: 5619588
  9. A quantitative study of the hemodynamics in the living microvascular system.
    Am J Anat. 1962 Mar;110:125-53 PMID: 13870035
  10. Blood viscosity: influence of erythrocyte deformation.
    Science. 1967 Aug 18;157(3790):827-9 PMID: 17842793
  11. Flow Characteristics of Human Erythrocytes through Polycarbonate Sieves.
    Science. 1967 Aug 18;157(3790):825-7 PMID: 17842792
Article Info
Journal
Biophysical journal
Abbr.
Biophys J
ISSN
0006-3495
Published
1971-03-00
Pages
252-64
Language
English
Region
United States
NLM ID
0370626
PMCID
PMC1483987
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]