Home LiteratureArticle Details
PMID: 6520216 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Evaluation of the AutoMicrobic system for identification and susceptibility testing of gram-negative bacilli.

Journal of clinical microbiology ·Vol. 20 ·No. 6 ·1984-12-00 ·Pages 1053-9

Woolfrey BF, Lally RT, Ederer MN, Quall CO

Abstract

The AutoMicrobic system (AMS) (Vitek Systems, Inc., Hazelwood, Mo.) was compared with the API-20E system for the identification of gram-negative bacilli by using 380 stock clinical isolates and 377 immediately encountered fresh clinical isolates. For the stock isolates, with Enterobacteriaceae-Plus Biochemical Cards and automated interpretation, 364 (95.8%) were in agreement to the species level. For the fresh clinical isolates, agreement at the genus and species levels was 89.7 and 85.9%, respectively, when Enterobacteriaceae-Plus Cards were interpreted by the AMS. Manual interpretation of Enterobacteriaceae-Plus Biochemical Cards improved species level agreement to 91.0%. Subsequent retesting of all discrepant isolates with the Gram-Negative Identification Card resulted in significant improvement of results, and for the stock and fresh clinical isolates, species level agreement was 98.7 and 97.3%, respectively. AMS susceptibility testing was evaluated by comparing ampicillin and cephalothin MICs determined in parallel by AMS and a reference broth microdilution test for stock isolates, and by comparison of AMS and standardized disk agar diffusion test results for fresh clinical isolates. For the stock isolates, AMS mean integer MICs approximated microdilution mean integer MICs with AMS, providing excellent MIC replicability. For ampicillin and cephalothin, 50 and 46.8%, respectively, of AMS integer MICs were within +/- 1 microgram/ml of the reference values, and 89.3 and 63.1% of AMS integer MICs were within +/- 2 micrograms/ml of the reference values. For the fresh clinical isolates, AMS and reference results were in disagreement for 4.5% of the antimicrobial agents tested, with 2.3% as a combination of "major" and "very major" errors.

MeSH Terms
Ampicillin/pharmacology Bacteria/classification,drug effects Cephalosporins/pharmacology Enterobacteriaceae/classification Humans Microbial Sensitivity Tests/methods
Chemicals
Cephalosporins Ampicillin
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Woolfrey B F
Lally R T
Ederer M N
Quall C O
References (11)
11 references, click to expand
  1. Evaluation of the AutoMicrobic system for identification of glucose-nonfermenting gram-negative rods.
    J Clin Microbiol. 1982 Feb;15(2):302-7 PMID: 7040451
  2. Identification of Enterobacteriaceae by the automicrobic system: Enterobacteriaceae biochemical cards versus Enterobacteriaceae-plus biochemical cards.
    J Clin Microbiol. 1982 Apr;15(4):575-81 PMID: 7040456
  3. Comparison of three automated systems for antimicrobial susceptibility testing of gram-negative bacilli.
    J Clin Microbiol. 1982 May;15(5):902-5 PMID: 7096560
  4. Reliability of early identifications obtained with Enterobacteriaceae-plus biochemical cards in the automicrobic system.
    J Clin Microbiol. 1982 Aug;16(2):257-65 PMID: 6749890
  5. Direct comparison of two mechanized systems for identification of gram-negative bacilli. Autobac ID system versus the auto microbic system (with EBC plus).
    Am J Clin Pathol. 1982 Oct;78(4):462-70 PMID: 6753560
  6. Rapid antimicrobial susceptibility testing of Gram-negative clinical isolates with the AutoMicrobic system.
    J Clin Microbiol. 1984 Jun;19(6):744-7 PMID: 6432832
  7. Comparison of two automated instrument systems for rapid susceptibility testing of gram-negative bacilli.
    J Clin Microbiol. 1983 Dec;18(6):1301-9 PMID: 6418754
  8. Error rates associated with the use of recently proposed breakpoints for testing Pseudomonas aeruginosa versus gentamicin, tobramycin, and amikacin by the standardized disk agar diffusion test.
    Antimicrob Agents Chemother. 1983 Nov;24(5):764-70 PMID: 6419674
  9. Clinical evaluation of new AMS GSC plus card.
    Diagn Microbiol Infect Dis. 1983 Jun;1(2):139-43 PMID: 6425001
  10. Evaluation of the automicrobic system for susceptibility testing of Pseudomonas aeruginosa to gentamicin, tobramycin, and amikacin.
    J Clin Microbiol. 1984 Apr;19(4):502-5 PMID: 6425360
  11. Evaluation of the AutoSCAN-3 and Sceptor systems for Enterobacteriaceae identification.
    J Clin Microbiol. 1983 May;17(5):807-13 PMID: 6345577
Article Info
Journal
Journal of clinical microbiology
Abbr.
J Clin Microbiol
ISSN
0095-1137
Published
1984-12-00
Pages
1053-9
Language
English
Region
United States
NLM ID
7505564
PMCID
PMC271516
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]