A rapid micro-scale method for the measurement of Haemoglobin A1(a+b+c).

Diabetologia ·Vol. 14 ·No. 3 ·1978-03-00 ·Pages 209-11

Welch SG, Boucher BJ

Abstract

A rapid method is described for the measurement of total glycosylated haemoglobins (HbA1(a+b+c). The procedure utilizes 0.05 ml of blood and takes forty minutes to complete manually. Eighty blood samples can be analysed without automation by one person in a day. Each analysis uses less than 2 mg of potassium cyanide, resulting in a method that is both safe and rapid for routine hospital laboratories. The inter-assay coefficient of variation was 4% and that for intra-assay measurements 3%, over the range 5-20%, HbA1(a+b+c). The method confirmed that the level of HbA1(a+b+c) is elevated in imperfectly controlled diabetics. Amongst patients with blood glucose levels of less than 10 mmol/l the mean level of HbA1(a+b+c) was found to be 8.5%; samples from 14 known diabetics gave a mean value of 10.9%, whereas 17 known non-diabetic samples gave a mean value of 8.3%. In the group of samples from 27 diabetic individuals with blood glucose levels above 10 mmol/l the mean level of HbA1(a+b+c) was found to be 13.5%.

MeSH Terms
Chromatography, Ion Exchange/methods Diabetes Mellitus/blood Hemoglobin A/analysis Hemoglobins/analysis Humans Microchemistry
Chemicals
Hemoglobins Hemoglobin A
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Welch S G
Boucher B J
References (4)
4 references, click to expand
  1. An abnormal hemoglobin in red cells of diabetics.
    Clin Chim Acta. 1968 Oct;22(2):296-8 PMID: 5687098
  2. Rapid estimation (2 1/2 hours) of glycosylated haemoglobin for routine purposes.
    Lancet. 1977 Jul 2;2(8027):16 PMID: 69103
  3. Correlation of glucose regulation and hemoglobin AIc in diabetes mellitus.
    N Engl J Med. 1976 Aug 19;295(8):417-20 PMID: 934240
  4. Red cell age-related changes of hemoglobins AIa+b and AIc in normal and diabetic subjects.
    J Clin Invest. 1976 Oct;58(4):820-4 PMID: 965489
Article Info
Journal
Diabetologia
Abbr.
Diabetologia
ISSN
0012-186X
Published
1978-03-00
Pages
209-11
Language
English
Region
Germany
NLM ID
0006777
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]