Abstract
Tests were performed using the sterile bag technique to determine the effects of type of sampling solution, use of antiseptic neutralizers, and solution temperature on the detection and quantitation of bacteria on hands. Using paired hand cultures, three sampling solutions were compared: quarter-strength Ringer solution, a phosphate buffer containing Triton X-100, and the same buffer containing antiseptic neutralizers. The phosphate buffer containing Triton X-100 was significantly better than quarter-strength Ringer solution in mean bacterial yield; the neutralizer-containing sampling solution was slightly better than Triton X-100-containing solution, although differences were not significant at the P = 0.05 level. Temperature (6 or 23 degrees C) of the sampling solution showed no consistent effect on bacterial yield from hands tested with the fluid containing neutralizers.
MeSH Terms
Adult
Aged
Anti-Infective Agents, Local
Bacteria/drug effects,isolation & purification
Bacteriological Techniques
Female
Hand/microbiology
Humans
Male
Phosphatidylcholines/pharmacology
Polyethylene Glycols/pharmacology
Polysorbates/pharmacology
Solutions
Temperature
Thiosulfates/pharmacology
Chemicals
Anti-Infective Agents, Local
Phosphatidylcholines
Polysorbates
Solutions
Thiosulfates
Polyethylene Glycols
lubrol
sodium thiosulfate
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Larson E L
Strom M S
Evans C A
References (18)
18 references, click to expand
-
Microcolony size of microbes on human skin.
J Med Microbiol. 1973 Aug;6(3):323-8
PMID: 4726334
-
Inactivating medium for hexachlorophene (G11) types of compounds and some substituted phenolic disinfectants.
Science. 1953 Sep 4;118(3062):274-6
PMID: 13089672
-
Re-evaluation of Scrub Technic for Preoperative Disinfection of the Surgeon's Hands.
Ann Surg. 1962 Jan;155(1):107-18
PMID: 17859692
-
Mode of transmission of Pseudomonas aeruginosa in a burn unit and an intensive care unit in a general hospital.
Appl Microbiol. 1972 Feb;23(2):309-12
PMID: 4622827
-
Evaluation of skin cleansing procedures using the wipe-rinse technique.
Health Lab Sci. 1974 Jul;11(3):182-7
PMID: 4209768
-
Effect of antimicrobial soap containing chlorhexidine on the microbial flora of skin.
Appl Environ Microbiol. 1976 Jun;31(6):931-5
PMID: 779648
-
Evaluation of hand antisepsis.
Arch Environ Health. 1969 May;18(5):781-3
PMID: 4976544
-
Role of hand contamination of personnel in the epidemiology of gram-negative nosocomial infections.
J Pediatr. 1975 Mar;86(3):433-7
PMID: 1167588
-
Differential quantitation of surface and subsurface bacteria of normal skin by the combined use of the cotton swab and the scrub methods.
J Clin Microbiol. 1976 Jun;3(6):576-81
PMID: 950377
-
Hands as route of transmission for Klebsiella species.
Br Med J. 1977 Nov 19;2(6098):1315-7
PMID: 589166
-
A new method for the quantitative investigation of cutaneous bacteria.
J Invest Dermatol. 1965 Dec;45(6):498-503
PMID: 5321315
-
A test for 'hygienic' hand disinfection.
J Clin Pathol. 1978 Oct;31(10):923-8
PMID: 101554
-
Disinfection of the hands of surgeons and nurses.
Br Med J. 1960 May 14;1(5184):1445-50
PMID: 14418523
-
Comparison of two methods for assessing the removal of total organisms and pathogens from the skin.
J Hyg (Lond). 1975 Oct;75(2):259-74
PMID: 1100713
-
An evaluation of techniques for sampling skin flora.
J Invest Dermatol. 1970 Feb;54(2):160-3
PMID: 4904886
-
A method for the in vivo evaluation of skin sanitizing soaps.
Appl Microbiol. 1954 Jul;2(4):202-4
PMID: 13181401
-
Improved experimental model for measuring skin degerming activity on the human hand.
Antimicrob Agents Chemother. 1972 Jul;2(1):8-15
PMID: 4670659
-
Failure of hand disinfection with frequent hand washing: a need for prolonged field studies.
J Hyg (Lond). 1977 Aug;79(1):107-19
PMID: 267663