[Thoracic radiography. Comparison of asymmetric screen-film, technic of mechanical homogenization, and conventional technics].

La Radiologia medica ·第 90 卷 ·第 1-2 期 ·1995-11-09

Ciccotosto C, Bartelli F, Bellelli M, Gavelli G, Guidotti A, Pirronti T, Bonomo L

摘要

This study was aimed at comparing three different systems, i.e., asymmetric screen-film, mechanical homogenized and conventional techniques, in standing frontal and lateral plain radiographs of the chest. Two hundred consecutive patients with normal posteroanterior (PA) and lateral films were randomly subdivided into 4 groups. Each group was submitted to chest radiographs with a different technique: asymmetric screen-film systems (InSight HC and High Light GCA), mechanical homogenized (Tau-Gil Homogenized) and conventional high-kilovoltage techniques. The exposure values for frontal projections ranged 110 kV (InSight HC) to 141 kV (Tau-Gil), while for lateral projections they ranged 123 kV (conventional technique) to 143 kV (Tau-Gil). Statistically significant differences were observed between the two asymmetric systems as regards exposure values, High Light exhibiting higher mean values in the frontal projection (t-test p < 0.05). Image quality was studied jointly by 3 experienced chest radiologists. The observers were asked to grade, on a 3-point ordinal scale, the conspicuity of mediastinal borders, of pulmonary vessels and of selected areas of lung parenchyma (i.e., retrocardiac, retrosternal and apical regions), as well as overall image quality on the frontal projection. The statistical analysis of paired differences was performed with the Mann-Whitney U-test. The asymmetric and the mechanical homogenized techniques were much better than the conventional technique in depicting tracheobronchial tree, retrocardiac parenchyma, azygos-esophageal recess and thoracic spine (p < 0.05). The mechanical homogenized system provided best overall image quality on frontal films, being superior to both InSight HC and conventional techniques, but not to the High Light GCA system; only the frontal projection obtained with the homogenized technique was compared, no filter being available for the lateral projection. When the two asymmetric systems were compared, the High Light system better depicted vascular structures on frontal films (p < 0.05), while apical areas were better demonstrated with the InSight system, namely with lateral films (p < 0.05).

文献信息
期刊
La Radiologia medica
期刊简称
Radiol Med
发表日期
1995-11-09
收录日期
1995-11-09
更新日期
2008-10-21
语言
ita
国家/地区
Italy
NLM ID
0177625
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]