Home LiteratureArticle Details
PMID: 7998683 Published · ppublish English Comparative Study Journal Article Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, P.H.S.

Lumped model of terminal aortic impedance in the dog.

Annals of biomedical engineering ·Vol. 22 ·No. 4 ·1994-00-00 ·Pages 381-91

Burattini R, Fogliardi R, Campbell KB

Abstract

The aim of this study was the formulation of a minimal lumped model of the aortic impedance as seen in the abdominal aorta just downstream of the origin of renal arteries. At this location simultaneous measurements of pressure and flow were taken in four anesthetized and open-chest dogs (weight, 30.9 +/- 5.8 kg) under basal, vasodilated (sodium nitroprusside) and vasoconstricted (methoxamine) conditions. Using these measurements we identified and compared three lumped models, A, B, and C, with decreasing complexity from A to C. The frequency response of these models was given the general form of peripheral resistance, Rp, multiplied by the ratio between (a) two zeros and two poles (model A); (b) two zeros and one pole (model B); and (c) one zero and one pole (model C). Rp was calculated as the ratio of mean pressure to mean flow. The other model parameters (time constants, damping factors, and natural frequencies) were estimated by minimizing the sum of squared differences between experimental and model generated pulsatile flows. After parameter estimation, the F-test was applied to compare the goodness of data fit obtained from the three models. Results of this test and the analysis of parameter estimation errors indicated that model B was preferable with respect to models A and C. The analysis of general model performance was followed by a consideration of alternative specific model structures that are physically realizable. With the aid of a determined model structure we evaluated the overall compliance of terminal aortic circulation under a variety of vascular states induced by injection of vasoactive agents.

MeSH Terms
Animals Aorta, Abdominal Aortic Diseases/physiopathology Bias Blood Circulation/drug effects,physiology Celiac Artery/drug effects,physiopathology Compliance Constriction, Pathologic Disease Models, Animal Dogs Evaluation Studies as Topic Hemodynamics/drug effects,physiology Mesenteric Arteries/drug effects,physiopathology Methoxamine/pharmacology Models, Cardiovascular Monitoring, Physiologic Nitroprusside/pharmacology Renal Artery/drug effects,physiopathology Reproducibility of Results Time Factors
Chemicals
Nitroprusside Methoxamine
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Burattini R
Department of Electronics and Automatica, University of Ancona, Italy.
Fogliardi R
Campbell K B
References (18)
18 references, click to expand
  1. Reduced models of arterial systems.
    IEEE Trans Biomed Eng. 1985 Feb;32(2):174-6 PMID: 3997173
  2. Effective distributed compliance of the canine descending aorta estimated by modified T-tube model.
    Am J Physiol. 1993 Jun;264(6 Pt 2):H1977-87 PMID: 8322928
  3. Impedance of arterial system simulated by viscoelastic t tubes terminated in windkessels.
    Am J Physiol. 1989 Apr;256(4 Pt 2):H1087-99 PMID: 2705551
  4. Two arterial effective reflecting sites may appear as one to the heart.
    Circ Res. 1991 Jan;68(1):85-99 PMID: 1984875
  5. Vascular impedance in studies of arterial and cardiac function.
    Physiol Rev. 1982 Apr;62(2):570-623 PMID: 6461866
  6. Estimation of total arterial compliance: an improved method and evaluation of current methods.
    Am J Physiol. 1986 Sep;251(3 Pt 2):H588-600 PMID: 3752271
  7. A simple algorithm for defining the mean cardiac cycle of aortic flow and pressure during steady state.
    Comput Biomed Res. 1985 Aug;18(4):303-12 PMID: 3840069
  8. Pressure and flow waves in systemic arteries and the anatomical design of the arterial system.
    J Appl Physiol. 1967 Aug;23(2):139-49 PMID: 5340142
  9. Arterial viscoelasticity: a generalized model. Effect on input impedance and wave travel in the systematic tree.
    J Biomech. 1970 May;3(3):357-79 PMID: 5521552
  10. Quantitative evaluation of the systemic arterial bed by parameter estimation of a simple model.
    Med Biol Eng Comput. 1980 Mar;18(2):153-66 PMID: 7392681
  11. Baroreceptor reflex control of arterial hemodynamics in the dog.
    Circ Res. 1975 Dec;37(6):772-86 PMID: 1192569
  12. Alterations with age in the viscoelastic properties of human arterial walls.
    Circ Res. 1966 Mar;18(3):278-92 PMID: 5904318
  13. Evaluation of hypercholesterol diet-induced changes in viscoelastic properties of carotid circulation in pigs.
    Am J Physiol. 1992 Dec;263(6 Pt 2):H1919-26 PMID: 1481915
  14. Pressure and tone dependence of coronary diastolic input impedance and capacitance.
    Am J Physiol. 1985 May;248(5 Pt 2):H700-11 PMID: 3993808
  15. An artificial arterial system for pumping hearts.
    J Appl Physiol. 1971 Nov;31(5):776-81 PMID: 5117196
  16. Pressure-flow relations in the vessels of the canine aortic arch.
    Am J Physiol. 1975 Jan;228(1):1-10 PMID: 1096641
  17. Dependence of wall stress in the human thoracic aorta on age and pressure.
    Circ Res. 1967 Mar;20(3):354-61 PMID: 6025615
  18. Beat-to-beat estimation of peripheral resistance and arterial compliance during pressure transients.
    Am J Physiol. 1987 Jun;252(6 Pt 2):H1275-83 PMID: 3591973
Article Info
Journal
Annals of biomedical engineering
Abbr.
Ann Biomed Eng
ISSN
0090-6964
Published
1994-00-00
Pages
381-91
Language
English
Region
United States
NLM ID
0361512
Subset
IM
Grants
NHLBI NIH HHS · HL-21462 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]