[A basic study of multi-gated single photon emission computed tomography with thallium-201].

Kaku igaku. The Japanese journal of nuclear medicine ·第 30 卷 ·第 9 期 ·1993-12-10

Sugioka Y, Adachi I, Tabuchi K, Saika Y, Tatsu Y, Nakata Y, Namba R, Nishigaki H, Sueyoshi K, Narabayashi I

摘要

A Multi-gated SPECT was acquired commonly in 64 x 64 matrix and 8 frames per cardiac cycle (64 x 64/8F). But it was not established that 64 x 64 matrix and 8 frames per cardiac cycle were the most suitable in multi-gated SPECT. Five normal volunteers were examined multi-gated 201Tl SPECT with 5 acquisition modes of 128 x 128 matrix/16 frames, 128 x 128/8F, 64 x 64/32F, 64 x 64/8F using multi-detector SPECT system (GCA-9300). And we calculated percent wall thickening (%WT) [%WT = (ES counts - ED counts)/ED counts] in 9 cases with 64 x 64/8F. The images quality of both 128 x 128/16F and 128 x 128/8F was not clear in compared with images of both 64 x 64/16F and 64 x 64/8F, because the end-diastolic phase of 128 x 128/16F images showed a decreased uptake of 201Tl in the antero-apical region. Although 64 x 64 (8) images had only 8 frames per cardiac cycle, we could observe systolic and diastolic phase and we could calculate %WT. The %WT (M +/- SD) of horizontal long axis images were 48 +/- 15 (sept. basal), 48 +/- 19 (sept. apical), 65 +/- 29 (apex), 49 +/- 22 (lat. apical) and 40 +/- 15 (lat. basal).(ABSTRACT TRUNCATED AT 250 WORDS)

文献信息
期刊
Kaku igaku. The Japanese journal of nuclear medicine
期刊简称
Kaku Igaku
ISSN
0022-7854
发表日期
1993-12-10
收录日期
1993-12-10
更新日期
2016-11-23
语言
jpn
国家/地区
Japan
NLM ID
2985202R
外部链接
PubMed 原文
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]