Home LiteratureArticle Details
PMID: 8364 Published · ppublish English Journal Article

Plasma insulin concentration during physiological variations in immunoreactive plasma secretin.

de Muckadell OB, Fahrenkrug J, Kühl C

Abstract

The effect of endogenous and exogenous secretin on fasting plasma insulin and glucose concentrations in peripheral venous blood was studied. In 10 non-diabetic subjects intragastric instillation of 300 ml 0.1 mol/l hydrochloric acid increased the plasma secretin concentration significantly. This increment did not influence insulin or glucose concentration. Control experiments with intragastric instillation of 300 ml of isotonic saline did not influence the plasma concentration of secretin, insulin or glucose. In four other non-diabetic persons no significant changes were found in plasma insulin or glucose concentration during an i.v. infusion of pure natural porcine secretin in doses of 0.1, 0.3, 1.0 and 3.0 clinical units/kg/h. The results suggest that secretin is without effect on insulin secretion in the fasting normal subject.

MeSH Terms
Adult Aged Blood Glucose/metabolism Fasting Humans Hydrogen-Ion Concentration Insulin/blood Middle Aged Radioimmunoassay Secretin/blood
Chemicals
Blood Glucose Insulin Secretin
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
de Muckadell O B
Fahrenkrug J
Kühl C
Article Info
Journal
Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme
Abbr.
Horm Metab Res
ISSN
0018-5043
Published
1976-07-00
Pages
253-6
Language
English
Region
Germany
NLM ID
0177722
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]