Effect of sustained load on dispersion of ventricular repolarization and conduction time in the isolated intact rabbit heart.

Journal of cardiovascular electrophysiology ·Vol. 7 ·No. 1 ·1996-01-00 ·Pages 9-16

Zabel M, Portnoy S, Franz MR

Abstract

It is well known that myocardial stretch can elicit ventricular arrhythmias in experimental models. However, previous reports have predominantly documented stretch-induced arrhythmias during short, pulsatile stretch. The arrhythmogenic mechanism of sustained static stretch is incompletely understood. To examine the influence of sustained load on several electrophysiologic parameters, a latex balloon was placed into the left ventricle of ten isolated Langendorff-perfused rabbit hearts and filled with a neutral volume of fluid. The heart was paced from a catheter inside the right ventricle (apicoseptal endocardial position), and the following parameters were studied during steady-state pacing with a cycle length of 500 msec (S1) and during extrastimulation (S2, base drive of 8 beats): monophasic action potential (MAP) durations at 90% repolarization (APD90) from 5 to 6 epicardial electrodes located on both ventricles and one right ventricular endocardial contact electrode; dispersion of APD90 (range of MAP durations from all electrodes); effective refractory period (ERP) and longest activation time (pacing stimulus to MAP upstroke). After baseline recordings, the balloon inside the left ventricle was filled with a volume of 1.0 mL of fluid by means of a servo-controlled pump. The ERP was significantly shortened from 198 +/- 9 msec at baseline to 183 +/- 8 msec during sustained load (P < 0.03). Similarly, the average APD90 was shortened from 180 +/- 5 msec at baseline to 175 +/- 6 msec during sustained load (P < 0.006) with steady-state pacing and from 178 +/- 6 msec to 170 +/- 8 msec during premature extrastimulation (P < 0.03). At the same time, dispersion of APD90 was increased from 27 +/- 5 msec to 38 +/- 6 msec (P < 0.002) during steady-state pacing and from 28 +/- 4 msec to 38 +/- 6 msec (P = 0.013) during premature extrastimulation. The longest activation time among all MAP recordings was increased from 39 +/- 2 msec to 43 +/- 3 msec (P = 0.003) during steady-state pacing and from 56 +/- 6 msec to 69 +/- 6 msec during premature extrastimulation (P < 0.003). Sustained load shortens the ERP and the mean APD90, and at the same time increases dispersion of APD90 and prolongs activation times. These findings provide additional insight into the arrhythmogenic mechanisms of sustained mechanical load.

MeSH Terms
Action Potentials Animals Arrhythmias, Cardiac/etiology Blood Pressure Heart Conduction System/physiology In Vitro Techniques Rabbits Refractory Period, Electrophysiological Stress, Mechanical Ventricular Function
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Zabel M
Division of Clinical Pharmacology, Georgetown University Medical Center, Washington, DC, USA.
Portnoy S
Franz M R
Article Info
Journal
Journal of cardiovascular electrophysiology
Abbr.
J Cardiovasc Electrophysiol
ISSN
1045-3873
Published
1996-01-00
Pages
9-16
Language
English
Region
United States
NLM ID
9010756
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]