Home LiteratureArticle Details
PMID: 9300301 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Transmembrane voltage changes produced by real and virtual electrodes during monophasic defibrillation shock delivered by an implantable electrode.

Journal of cardiovascular electrophysiology ·Vol. 8 ·No. 9 ·1997-09-00 ·Pages 1031-45

Efimov IR, Cheng YN, Biermann M, Van Wagoner DR, Mazgalev TN, Tchou PJ

Abstract

Epicardial point stimulation produces nonuniform changes in the transmembrane voltage of surrounding cells with simultaneous occurrence of areas of transient positive and negative polarization. This is the phenomenon of virtual electrode. We sought to characterize the responses of epicardial ventricular tissue to the application of monophasic electric shocks from an internal transvenous implantable cardioverter defibrillator (ICD) lead. Langendorff-perfused rabbit hearts (n = 12) were stained with di-4-ANEPPS. A 9-mm-long distal electrode was placed in the right ventricle. A 6-cm proximal electrode was positioned horizontally 3 cm posteriorly and 1 cm superiorly with respect to the heart. Monophasic anodal and cathodal pulses were produced by discharging a 150-microF capacitor. Shocks were applied either during the plateau phase of an action potential (AP) or during ventricular fibrillation. Leading-edge voltage of the pulse was 50 to 150 V, and the pulse duration was 10 msec. Transmembrane voltage was optically recorded during application of the shock, simultaneously from 256 sites on a 11 x 11 mm area of the anterior right ventricular epicardium directly transmural to the distal electrode. The shock effect was evaluated by determining the difference between the AP affected by the shock and the normal AP. During cathodal stimulation an area of depolarization near the electrode was observed, surrounded by areas of hyperpolarization. The amplitude of polarization gradually decreased in areas far from the electrode. Inverting shock polarity reversed this effect. ICD monophasic defibrillation shocks create large dynamically interacting areas of both negative and positive polarization.

MeSH Terms
Action Potentials Animals Cardiac Pacing, Artificial/methods Defibrillators, Implantable Electric Countershock/instrumentation,methods Electrodes, Implanted Female Fluorescence Image Interpretation, Computer-Assisted Male Models, Cardiovascular Rabbits Signal Processing, Computer-Assisted Ventricular Fibrillation/physiopathology
Authors & Affiliations
6 authors, click to expand affiliations / ORCID
Efimov I R
Department of Cardiology, Cleveland Clinic Foundation, OH 44195, USA. [email protected]
Cheng Y N
Biermann M
Van Wagoner D R
Mazgalev T N
Tchou P J
Article Info
Journal
Journal of cardiovascular electrophysiology
Abbr.
J Cardiovasc Electrophysiol
ISSN
1045-3873
Published
1997-09-00
Pages
1031-45
Language
English
Region
United States
NLM ID
9010756
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]