Home LiteratureArticle Details
PMID: 9879641 Published · ppublish English Comparative Study Journal Article Multicenter Study Research Support, Non-U.S. Gov't

Reference method for detection of Pgp mediated multidrug resistance in human hematological malignancies: a method validated by the laboratories of the French Drug Resistance Network.

Cytometry ·Vol. 34 ·No. 6 ·1998-12-15 ·页码 248-56

Huet S, Marie JP, Gualde N, Robert J

Abstract

Multidrug resistance (MDR) associated with overexpression of the MDR1 gene and of its product, P-glycoprotein (Pgp), plays an important role in limiting cancer treatment efficacy. Many studies have investigated Pgp expression in clinical samples of hematological malignancies but failed to give definitive conclusion on its usefulness. One convenient method for fluorescent detection of Pgp in malignant cells is flow cytometry which however gives variable results from a laboratory to another one, partly due to the lack of a reference method rigorously tested. The purpose of this technical note is to describe each step of a reference flow cytometric method. The guidelines for sample handling, staining and analysis have been established both for Pgp detection with monoclonal antibodies directed against extracellular epitopes (MRK16, UIC2 and 4E3), and for Pgp functional activity measurement with Rhodamine 123 as a fluorescent probe. Both methods have been validated on cultured cell lines and clinical samples by 12 laboratories of the French Drug Resistance Network. This cross-validated multicentric study points out crucial steps for the accuracy and reproducibility of the results, like cell viability, data analysis and expression.

MeSH 主题词
ATP Binding Cassette Transporter, Subfamily B, Member 1/blood Cell Line Drug Resistance, Multiple Evaluation Studies as Topic Flow Cytometry/methods Hematologic Neoplasms/blood Humans Reference Standards Reproducibility of Results Rhodamine 123
化学物质
ATP Binding Cassette Transporter, Subfamily B, Member 1 Rhodamine 123
作者与单位
共 4 位作者,点击展开单位 / ORCID
Huet S
Laboratoire d'Immunologie Cytométrie, Institut Bergonié, Bordeaux, France. [email protected]
Marie J P
Gualde N
Robert J
Article Info
Journal
Cytometry
Abbr.
Cytometry
ISSN
0196-4763
Corresponding email
Published
1998-12-15
页码
248-56
Language
English
Country/Region
United States
NLM ID
8102328
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]