Abstract
Patients who receive transcatheter aortic valve replacement are at risk for leaflet thrombosis-related complications, and can benefit from continuous, longitudinal monitoring of the prosthesis. Conventional angiography modalities are expensive, hospital-centric and either invasive or employ potentially nephrotoxic contrast agents, which preclude their routine use. Heart sounds have been long recognized to contain valuable information about individual valve function, but the skill of auscultation is in decline due to its heavy reliance on the physician's proficiency leading to poor diagnostic repeatability. This subjectivity in diagnosis can be alleviated using machine learning techniques for anomaly detection. We present a computational and data-driven proof-of-concept analysis of a novel, auscultation-based technique for monitoring aortic valve, which is practical, non-invasive, and non-toxic. However, the underlying mechanisms leading to physiological and pathological heart sounds are not well-understood, which hinders development of such a technique. We first address this by performing direct numerical simulations of the complex interactions between turbulent blood flow in a canonical ascending aorta model and dynamic valve motion in 29 cases with healthy and stenotic valves. Using the turbulent pressure fluctuations on the aorta lumen boundary, we model the propagation of heart sounds, as elastic waves, through the patient's thorax. The heart sound may be recorded on the epidermal surface using a stethoscope/phonocardiograph. This approach allows us to correlate instantaneous hemodynamic phenomena and valve motion with the acoustic response. From this dataset we extract "acoustic signatures" of healthy and stenotic valves based on principal components of the recorded sound. These signatures are used to train a linear discriminant classifier by maximizing correlation between recorded heart sounds and valve status. We demonstrate that this classifier is capable of accurate prospective detection of anomalous valve function and that the principal component-based signatures capture prominent audible features of heart sounds, which have been historically used by physicians for diagnosis. Further development of such technology can enable inexpensive, safe and patient-centric at-home monitoring, and can extend beyond transcatheter valves to surgical as well as native valves.
Keywords
TAVR
anomaly detection
aortic valve murmurs
computational fluid dynamics
hemoacoustics
supervised learning
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Bailoor Shantanu
Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD, United States.
Seo Jung-Hee
Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD, United States.
Schena Stefano
Division of Cardiac Surgery, Johns Hopkins Medical Institute, Baltimore, MD, United States.
Mittal Rajat
Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD, United States.
Conflict of Interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References (28)
28 references, click to expand
-
Prosthetic Valve Monitoring via In Situ Pressure Sensors: In Silico Concept Evaluation using Supervised Learning.
Cardiovasc Eng Technol. 2022 Feb;13(1):90-103
PMID: 34145555
-
Boundary element model for simulating sound propagation and source localization within the lungs.
J Acoust Soc Am. 2007 Jul;122(1):657-61
PMID: 17614522
-
Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study.
Lancet. 2017 Jun 17;389(10087):2383-2392
PMID: 28330690
-
Remote Monitoring of Patients Undergoing Transcatheter Aortic Valve Replacement: A Framework for Postprocedural Telemonitoring.
JMIR Cardio. 2018 Mar 16;2(1):e9
PMID: 31758782
-
Deaths: final data for 2005.
Natl Vital Stat Rep. 2008 Apr 24;56(10):1-120
PMID: 18512336
-
A Novel Sensorized Heart Valve Prosthesis: Preliminary In Vitro Evaluation.
Sensors (Basel). 2018 Nov 13;18(11):
PMID: 30428516
-
Clinical Valve Thrombosis and Subclinical Leaflet Thrombosis Following Transcatheter Aortic Valve Replacement: Is There a Need for a Patient-Tailored Antithrombotic Therapy?
Front Cardiovasc Med. 2019 Apr 18;6:44
PMID: 31058168
-
Transcatheter valve-in-valve implantation for failed surgical bioprosthetic valves.
J Am Coll Cardiol. 2011 Nov 15;58(21):2196-209
PMID: 22078426
-
Infective endocarditis after transcatheter aortic valve implantation: results from a large multicenter registry.
Circulation. 2015 May 5;131(18):1566-74
PMID: 25753535
-
Improvement of cardiac auscultation skills in pediatric residents with training.
Clin Pediatr (Phila). 2007 Apr;46(3):236-40
PMID: 17416879
-
Thrombus formation following transcatheter aortic valve replacement.
JACC Cardiovasc Interv. 2015 Apr 27;8(5):728-39
PMID: 25946447
-
Deep Neural Networks for the Recognition and Classification of Heart Murmurs Using Neuromorphic Auditory Sensors.
IEEE Trans Biomed Circuits Syst. 2018 Feb;12(1):24-34
PMID: 28952948
-
Acoustic radiation from a fluid-filled, subsurface vascular tube with internal turbulent flow due to a constriction.
J Acoust Soc Am. 2005 Aug;118(2):1193-209
PMID: 16158674
-
Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care.
Nat Commun. 2014 Oct 06;5:5028
PMID: 25284074
-
Left ventricular outflow tract shape after aortic valve replacement with St. Jude Trifecta prosthesis.
Echocardiography. 2018 Mar;35(3):329-336
PMID: 29272555
-
Cardiac auscultatory skills of physicians-in-training: a comparison of three English-speaking countries.
Am J Med. 2001 Feb 15;110(3):210-6
PMID: 11182108
-
The geometry of the aortic root in health, at valve disease and after valve replacement.
J Biomech. 1990;23(2):181-91
PMID: 2312522
-
A computational study of the hemodynamics of bioprosthetic aortic valves with reduced leaflet motion.
J Biomech. 2021 May 7;120:110350
PMID: 33743394
-
Transcatheter Aortic Valve Replacement: Comprehensive Review and Present Status.
Tex Heart Inst J. 2017 Feb 1;44(1):29-38
PMID: 28265210
-
Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves.
N Engl J Med. 2015 Nov 19;373(21):2015-24
PMID: 26436963
-
Side effects of radiographic contrast media: pathogenesis, risk factors, and prevention.
Biomed Res Int. 2014;2014:741018
PMID: 24895606
-
2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines.
J Am Coll Cardiol. 2014 Jun 10;63(22):2438-88
PMID: 24603192
-
Deep Learning Algorithm for Automated Cardiac Murmur Detection via a Digital Stethoscope Platform.
J Am Heart Assoc. 2021 May 4;10(9):e019905
PMID: 33899504
-
Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients.
J Am Coll Cardiol. 2019 Sep 24;74(12):1532-1540
PMID: 31537261
-
Paravalvular leak after transcatheter aortic valve replacement: the new Achilles' heel? A comprehensive review of the literature.
J Am Coll Cardiol. 2013 Mar 19;61(11):1125-36
PMID: 23375925
-
Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients.
N Engl J Med. 2017 Apr 6;376(14):1321-1331
PMID: 28304219
-
Aortic Stenosis: Diagnosis and Treatment.
Am Fam Physician. 2016 Mar 1;93(5):371-8
PMID: 26926974
-
A VERSATILE SHARP INTERFACE IMMERSED BOUNDARY METHOD FOR INCOMPRESSIBLE FLOWS WITH COMPLEX BOUNDARIES.
J Comput Phys. 2008;227(10):4825-4852
PMID: 20216919