Detecting Aortic Valve Anomaly From Induced Murmurs: Insights From Computational Hemodynamic Models.

Frontiers in physiology ·Vol. 12 ·2021-00-00 ·Pages 734224

Bailoor S, Seo JH, Schena S, Mittal R

Abstract

Patients who receive transcatheter aortic valve replacement are at risk for leaflet thrombosis-related complications, and can benefit from continuous, longitudinal monitoring of the prosthesis. Conventional angiography modalities are expensive, hospital-centric and either invasive or employ potentially nephrotoxic contrast agents, which preclude their routine use. Heart sounds have been long recognized to contain valuable information about individual valve function, but the skill of auscultation is in decline due to its heavy reliance on the physician's proficiency leading to poor diagnostic repeatability. This subjectivity in diagnosis can be alleviated using machine learning techniques for anomaly detection. We present a computational and data-driven proof-of-concept analysis of a novel, auscultation-based technique for monitoring aortic valve, which is practical, non-invasive, and non-toxic. However, the underlying mechanisms leading to physiological and pathological heart sounds are not well-understood, which hinders development of such a technique. We first address this by performing direct numerical simulations of the complex interactions between turbulent blood flow in a canonical ascending aorta model and dynamic valve motion in 29 cases with healthy and stenotic valves. Using the turbulent pressure fluctuations on the aorta lumen boundary, we model the propagation of heart sounds, as elastic waves, through the patient's thorax. The heart sound may be recorded on the epidermal surface using a stethoscope/phonocardiograph. This approach allows us to correlate instantaneous hemodynamic phenomena and valve motion with the acoustic response. From this dataset we extract "acoustic signatures" of healthy and stenotic valves based on principal components of the recorded sound. These signatures are used to train a linear discriminant classifier by maximizing correlation between recorded heart sounds and valve status. We demonstrate that this classifier is capable of accurate prospective detection of anomalous valve function and that the principal component-based signatures capture prominent audible features of heart sounds, which have been historically used by physicians for diagnosis. Further development of such technology can enable inexpensive, safe and patient-centric at-home monitoring, and can extend beyond transcatheter valves to surgical as well as native valves.

Keywords
TAVR anomaly detection aortic valve murmurs computational fluid dynamics hemoacoustics supervised learning
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Bailoor Shantanu
Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD, United States.
Seo Jung-Hee
Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD, United States.
Schena Stefano
Division of Cardiac Surgery, Johns Hopkins Medical Institute, Baltimore, MD, United States.
Mittal Rajat
Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD, United States.
Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References (28)
28 references, click to expand
  1. Prosthetic Valve Monitoring via In Situ Pressure Sensors: In Silico Concept Evaluation using Supervised Learning.
    Cardiovasc Eng Technol. 2022 Feb;13(1):90-103 PMID: 34145555
  2. Boundary element model for simulating sound propagation and source localization within the lungs.
    J Acoust Soc Am. 2007 Jul;122(1):657-61 PMID: 17614522
  3. Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study.
    Lancet. 2017 Jun 17;389(10087):2383-2392 PMID: 28330690
  4. Remote Monitoring of Patients Undergoing Transcatheter Aortic Valve Replacement: A Framework for Postprocedural Telemonitoring.
    JMIR Cardio. 2018 Mar 16;2(1):e9 PMID: 31758782
  5. Deaths: final data for 2005.
    Natl Vital Stat Rep. 2008 Apr 24;56(10):1-120 PMID: 18512336
  6. A Novel Sensorized Heart Valve Prosthesis: Preliminary In Vitro Evaluation.
    Sensors (Basel). 2018 Nov 13;18(11): PMID: 30428516
  7. Clinical Valve Thrombosis and Subclinical Leaflet Thrombosis Following Transcatheter Aortic Valve Replacement: Is There a Need for a Patient-Tailored Antithrombotic Therapy?
    Front Cardiovasc Med. 2019 Apr 18;6:44 PMID: 31058168
  8. Transcatheter valve-in-valve implantation for failed surgical bioprosthetic valves.
    J Am Coll Cardiol. 2011 Nov 15;58(21):2196-209 PMID: 22078426
  9. Infective endocarditis after transcatheter aortic valve implantation: results from a large multicenter registry.
    Circulation. 2015 May 5;131(18):1566-74 PMID: 25753535
  10. Improvement of cardiac auscultation skills in pediatric residents with training.
    Clin Pediatr (Phila). 2007 Apr;46(3):236-40 PMID: 17416879
  11. Thrombus formation following transcatheter aortic valve replacement.
    JACC Cardiovasc Interv. 2015 Apr 27;8(5):728-39 PMID: 25946447
  12. Deep Neural Networks for the Recognition and Classification of Heart Murmurs Using Neuromorphic Auditory Sensors.
    IEEE Trans Biomed Circuits Syst. 2018 Feb;12(1):24-34 PMID: 28952948
  13. Acoustic radiation from a fluid-filled, subsurface vascular tube with internal turbulent flow due to a constriction.
    J Acoust Soc Am. 2005 Aug;118(2):1193-209 PMID: 16158674
  14. Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care.
    Nat Commun. 2014 Oct 06;5:5028 PMID: 25284074
  15. Left ventricular outflow tract shape after aortic valve replacement with St. Jude Trifecta prosthesis.
    Echocardiography. 2018 Mar;35(3):329-336 PMID: 29272555
  16. Cardiac auscultatory skills of physicians-in-training: a comparison of three English-speaking countries.
    Am J Med. 2001 Feb 15;110(3):210-6 PMID: 11182108
  17. The geometry of the aortic root in health, at valve disease and after valve replacement.
    J Biomech. 1990;23(2):181-91 PMID: 2312522
  18. A computational study of the hemodynamics of bioprosthetic aortic valves with reduced leaflet motion.
    J Biomech. 2021 May 7;120:110350 PMID: 33743394
  19. Transcatheter Aortic Valve Replacement: Comprehensive Review and Present Status.
    Tex Heart Inst J. 2017 Feb 1;44(1):29-38 PMID: 28265210
  20. Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves.
    N Engl J Med. 2015 Nov 19;373(21):2015-24 PMID: 26436963
  21. Side effects of radiographic contrast media: pathogenesis, risk factors, and prevention.
    Biomed Res Int. 2014;2014:741018 PMID: 24895606
  22. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines.
    J Am Coll Cardiol. 2014 Jun 10;63(22):2438-88 PMID: 24603192
  23. Deep Learning Algorithm for Automated Cardiac Murmur Detection via a Digital Stethoscope Platform.
    J Am Heart Assoc. 2021 May 4;10(9):e019905 PMID: 33899504
  24. Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients.
    J Am Coll Cardiol. 2019 Sep 24;74(12):1532-1540 PMID: 31537261
  25. Paravalvular leak after transcatheter aortic valve replacement: the new Achilles' heel? A comprehensive review of the literature.
    J Am Coll Cardiol. 2013 Mar 19;61(11):1125-36 PMID: 23375925
  26. Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients.
    N Engl J Med. 2017 Apr 6;376(14):1321-1331 PMID: 28304219
  27. Aortic Stenosis: Diagnosis and Treatment.
    Am Fam Physician. 2016 Mar 1;93(5):371-8 PMID: 26926974
  28. A VERSATILE SHARP INTERFACE IMMERSED BOUNDARY METHOD FOR INCOMPRESSIBLE FLOWS WITH COMPLEX BOUNDARIES.
    J Comput Phys. 2008;227(10):4825-4852 PMID: 20216919
Article Info
Journal
Frontiers in physiology
Abbr.
Front Physiol
ISSN
1664-042X
Published
2021-00-00
Epub
2021-00-06
Pages
734224
Language
English
Region
Switzerland
NLM ID
101549006
PMCID
PMC8526559
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]