Protective isolation in a burns unit: the use of plastic isolators and air curtains.

The Journal of hygiene ·Vol. 69 ·No. 4 ·1971-12-00 ·Pages 529-46

Lowbury EJ, Babb JR, Ford PM

Abstract

The use of plastic isolators and of an ;air curtain' isolator for protection of patients against infection was studied in a burns unit.Preliminary bacteriological tests showed that very few airborne bacteria gained access to a plastic ventilated isolator; even when the filter and pre-filter were removed from the air inflow, settle-plate counts inside the isolator were much lower than those in the open ward, but the difference was smaller in tests made with an Anderson air sampler, which showed also that fewer large bacteria-carrying particles appeared inside the isolator than outside it. An open-topped isolator allowed virtually free access of bacteria from ambient air. The numbers of airborne bacteria inside an air curtain were appreciably lower than the counts of airborne bacteria in the open ward, but not as low as those in the plastic ventilated isolator.Controlled trials of isolators were made on patients with fresh burns of 4-30% of the body surface; the patients were given no topical chemoprophylaxis against Staphylococcus aureus or Gram-negative bacilli. Patients treated in plastic isolators showed a significantly lower incidence of infection with Pseudomonas aeruginosa than those treated in the open ward; this protective effect was shown by isolators with or without filters or with an open top. Ventilated isolators, which protected patients against personal contact and airborne infection, gave a limited protection against multi-resistant ;hospital' strains of Staph. aureus, but no such protection was given by an open-topped isolator, which protected only against personal contact infection, or by air curtains, which protected only against airborne infection; the air curtain gave no protection against Ps. aeruginosa, and there was no evidence of protection by any isolator against Proteus spp. and coliform bacilli.Both the controlled trials and evidence from the bacteriology of air, hands, fomites and rectal and nasal swabs taken on admission and later, supported the view that Ps. aeruginosa is transferred mainly by personal contact, Staph. aureus probably by air as well as by contact and coliform bacilli mainly by self infection with faecal flora, many of which are first acquired from the hospital environment in food or on fomites.The use of plastic isolators is cumbersome, and of limited value except in the control of infection with Ps. aeruginosa. For this reason and because of the effectiveness of topical chemoprophylaxis such isolators are unlikely to have more than an occasional use in the treatment of burns. Though air curtains greatly reduce airborne contamination, their use in a burns unit does not appear to protect patients against infection when the alternative (and, for Ps. aeruginosa, more important) routes of contamination by personal contact and fomites are left open.

MeSH Terms
Air Microbiology Burns/therapy Child Cross Infection/prevention & control Drug Resistance, Microbial Feces/microbiology Hand/microbiology Hospital Departments Humans Nose/microbiology Patient Isolators Plastics Proteus Pseudomonas Infections Pseudomonas aeruginosa Rectum/microbiology Staphylococcal Infections/prevention & control
Chemicals
Plastics
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Lowbury E J
Babb J R
Ford P M
References (10)
10 references, click to expand
  1. Bacteriological control of aureomycin therapy.
    Lancet. 1951 Jan 13;1(6646):87-9 PMID: 14795774
  2. Antiseptic and aseptic prophylaxis for burns: use of silver nitrate and of isolators.
    Br Med J. 1966 Nov 26;2(5525):1288-94 PMID: 4958926
  3. Gram-negative bacilli in burns.
    J Clin Pathol. 1969 Nov;22(6):634-41 PMID: 4312399
  4. Protective isolation in single-bed rooms: studies in a modified hospital ward.
    J Hyg (Lond). 1971 Dec;69(4):511-27 PMID: 5289715
  5. Air-conditioning with filtered air for dressing burns.
    Lancet. 1954 Feb 6;266(6806):292-4 PMID: 13131845
  6. Identification of Staphylococcus pyogenes by the phosphatase reaction.
    J Pathol Bacteriol. 1951 Jan;63(1):65-8 PMID: 14832691
  7. APPLICATION OF THE TECHNOLOGY OF THE GERMFREE LABORATORY TO SPECIAL PROBLEMS OF PATIENT CARE.
    Am J Surg. 1964 May;107:710-22 PMID: 14166206
  8. Protection from microbial contamination in a room ventilated by a uni-directional air flow.
    J Hyg (Lond). 1969 Mar;67(1):95-106 PMID: 4993557
  9. The epidemiology of infection with Pseudomonas pyocyanea in a burns unit.
    J Hyg (Lond). 1954 Sep;52(3):403-16 PMID: 13212044
  10. Infection of burns.
    Br Med J. 1960 Apr 2;1(5178):994-1001 PMID: 13856094
Article Info
Journal
The Journal of hygiene
Abbr.
J Hyg (Lond)
ISSN
0022-1724
Published
1971-12-00
Pages
529-46
Language
English
Region
England
NLM ID
0375374
PMCID
PMC2131052
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]