Home LiteratureArticle Details
PMID: 5289715 Published · ppublish English Journal Article

Protective isolation in single-bed rooms: studies in a modified hospital ward.

The Journal of hygiene ·Vol. 69 ·No. 4 ·1971-12-00 ·Pages 511-27

Ayliffe GA, Collins BJ, Lowbury EJ, Wall M

Abstract

Studies were made in a modified hospital ward containing 19 beds, 14 of them in the open ward, one in a window-ventilated side-room, two in rooms with partial-recirculation ventilators giving 7-10 air changes per hour, and two in self-contained isolation suites with plenum ventilation (20 air changes per hour), ultra-violet (UV) barriers at doorways and airlocks.Preliminary tests with aerosols of tracer bacteria showed that few bacteria entered the plenum or recirculation-ventilated rooms. Bacteria released inside mechanically ventilated cubicles escaped into the corridor, but this transfer was reduced by the presence of an airlock. UV barriers at the entrance to the airlock and the cubicle reduced the transfer of bacteria from cubicle to corridor.During a period of 4 years while the ward was in use for surgical and gynaecological patients, the incidence of post-operative sepsis and colonization of wounds by multiple-resistant Staphylococcus aureus was lower (though not significantly lower) in the plenum-ventilated rooms than in the open ward, the recirculator-ventilated cubicles and the window-ventilated cubicles. Nasal acquisition of multiple-resistant Staph. aureus was significantly less common in the plenum-ventilated than in the recirculator-ventilated cubicles and in the other areas. Mean counts of bacteria on settle-plates were significantly lower in the plenum-ventilated cubicles than in the other areas; mean settle-plate counts in the recirculator-ventilated cubicles were significantly lower than in the open ward and in the window-ventilated side-room; similar results were shown by slit-sampling of air. Mean settle-plate counts were significantly lower in all areas when the ward was occupied by female patients. Staph. aureus was rarely carried by air from plenum-ventilated or other cubicles to the open ward, or from the open ward to the cubicles; though staphylococci were transferred from one floor area to another, they did not appear to be redispersed into the air in sufficient numbers to infect the patients. Ultra-violet irradiation caused a significant reduction in the total and staphylococcal counts from the floors of airlocks, and a significant reduction of total counts in the air.

MeSH Terms
Air Microbiology Carrier State/microbiology Cross Infection/epidemiology Drug Resistance, Microbial Female Hospital Design and Construction Humans Nose Patient Isolators Sex Factors Staphylococcus/drug effects Surgical Wound Infection/epidemiology,microbiology Ultraviolet Rays Ventilation
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Ayliffe G A
Collins B J
Lowbury E J
Wall M
References (16)
16 references, click to expand
  1. Antiseptic and aseptic prophylaxis for burns: use of silver nitrate and of isolators.
    Br Med J. 1966 Nov 26;2(5525):1288-94 PMID: 4958926
  2. Ward floors and other surfaces as reservoirs of hospital infection.
    J Hyg (Lond). 1967 Dec;65(4):515-36 PMID: 4864325
  3. Design and use of plastic tents for isolation of patients prone to infection.
    Lancet. 1968 Dec 28;2(7583):1376-7 PMID: 4177935
  4. Nasal acquisition of Staphylococcus aureus in a subdivided and mechanically ventilated ward: endemic prevalence of a single staphylococcal strain.
    J Hyg (Lond). 1970 Sep;68(3):417-33 PMID: 5272345
  5. Staphylococcal infection in subdivided general surgical wards.
    J Hyg (Lond). 1970 Dec;68(4):531-47 PMID: 5275708
  6. Ward design in relation to postoperative wound infection. I.
    Br Med J. 1971 Jan 9;1(5740):67-72 PMID: 5539177
  7. Bacteriological observations in a mechanically ventilated experimental ward and in two open-plan wards.
    J Med Microbiol. 1969 Aug;2(3):335-45 PMID: 5405713
  8. Protective isolation in a burns unit: the use of plastic isolators and air curtains.
    J Hyg (Lond). 1971 Dec;69(4):529-46 PMID: 5002642
  9. Bacteriological control of aureomycin therapy.
    Lancet. 1951 Jan 13;1(6646):87-9 PMID: 14795774
  10. Identification of Staphylococcus pyogenes by the phosphatase reaction.
    J Pathol Bacteriol. 1951 Jan;63(1):65-8 PMID: 14832691
  11. Air-conditioning with filtered air for dressing burns.
    Lancet. 1954 Feb 6;266(6806):292-4 PMID: 13131845
  12. Environmental staphylococcal contamination.
    Lancet. 1960 Mar 26;1(7126):670-3 PMID: 13824125
  13. Isolation for the control of staphylococcal infection in surgical wards.
    Br Med J. 1962 Aug 4;2(5300):275-82 PMID: 14007220
  14. MEASUREMENT OF THE BACTERIAL CONTAMINATION ON SURFACES IN HOSPITALS.
    Public Health Rep. 1964 Nov;79:1021-4 PMID: 14212586
  15. DISPERSAL OF STAPHYLOCOCCUS AUREUS BY PATIENTS AND SURGICAL STAFF.
    Lancet. 1965 Feb 27;1(7383):480-3 PMID: 14241900
  16. AN ISOLATION WARD FOR PATIENTS WITH STAPHYLOCOCCAL SEPSIS.
    Lancet. 1965 Aug 28;2(7409):426-9 PMID: 14346768
Article Info
Journal
The Journal of hygiene
Abbr.
J Hyg (Lond)
ISSN
0022-1724
Published
1971-12-00
Pages
511-27
Language
English
Region
England
NLM ID
0375374
PMCID
PMC2131037
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]