Variables of the rubella hemagglutination-inhibition test system and their effect on antigen and antibody titers.

Applied microbiology ·Vol. 19 ·No. 3 ·1970-03-00 ·Pages 491-504

Schmidt NJ, Lennette EH

Abstract

A systematic study was made of certain variables of the rubella hemagglutination-inhibition (HI) test system and their effect on antigen and antibody titers. Erythrocytes from pigeons and 1-day-old chicks gave similar antigen and antibody titers, but goose erythrocytes gave lower titers. Indicator erythrocytes could be stored in Alsever's solution at 4 C for as long as 2 weeks without losing sensitivity in hemagglutination (HA) and HI tests. Antigen titers varied by eightfold or more in different diluent systems; titers were generally higher at pH 6.2 than at pH 7.2. A diluent without Ca(2+) gave antigen titers as high as those obtained in diluents with added Ca(2+) ions. Antibody titers also varied in different diluent systems. HEPES diluents at pH 6.2 gave higher antibody titers than those obtained in other diluents, but occasional "false-positive" inhibition reactions were seen. Kaolin suspended in borate saline at pH 9.0 effectively removed inhibitor from sera without absorbing specific antibody, but at pH 7.3 it removed various amounts of specific antibody. Antibody titers of sera treated with kaolin at pH 9.0 were similar to those of sera treated with heparin-MnCl(2); treatment with dextran sulfate-CaCl(2) gave lower antibody titers. Antigens varied widely in sensitivity for detecting HI antibody and in the ability to detect diagnostically significant increases in antibody. Sensitivity in detecting antibody was not related to the HA titer of the antigens. Tween-ether-treated antigens gave lower antibody titers but were more reliable than corresponding untreated antigens for serological diagnosis of infection.

MeSH Terms
Animals Antibodies Antigens Buffers Calcium Chickens Columbidae Complement Fixation Tests Erythrocytes/immunology Geese Hemagglutination Inhibition Tests Hemagglutination, Viral Hydrogen-Ion Concentration Immune Sera Ions Kaolin Neutralization Tests Rubella/diagnosis
Chemicals
Antibodies Antigens Buffers Immune Sera Ions Kaolin Calcium
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Schmidt N J
Lennette E H
References (17)
17 references, click to expand
  1. Rubella complement-fixing antigens derived from the fluid and cellular phases of infected BHK-21 cells: extraction of cell-associated antigen with alkaline buffers.
    J Immunol. 1966 Dec;97(6):815-21 PMID: 5955833
  2. Techniques for hemagglutination and hemagglutination-inhibition with arthropod-borne viruses.
    Am J Trop Med Hyg. 1958 Sep;7(5):561-73 PMID: 13571577
  3. The effect of kaolin on immunoglobulins: an improved technique to remove the nonspecific serum inhibitor of reovirus hemagglutination.
    J Immunol. 1967 Jun;98(6):1136-42 PMID: 4165228
  4. Rubella hemagglutinin prepared with alkaline extraction of virus grown in suspension culture of BHK-21 cells.
    Proc Soc Exp Biol Med. 1967 May;125(1):162-7 PMID: 6027517
  5. A comparison of the haemagglutination-inhibition test and the neutralisation test for the detection of rubella antibody.
    Lancet. 1967 Jul 22;2(7508):182-4 PMID: 4165706
  6. Rubella hemagglutinin prepared in serum free suspension culture of BHK-21 cells.
    Ann Med Exp Biol Fenn. 1967;45(2):182-5 PMID: 6049273
  7. The hemagglutination inhibition test for rubella: a comparison of its sensitivity to that of neutralization, complement fixation and fluorescent antibody tests for diagnosis of infection and determination of immunity status.
    J Immunol. 1967 Oct;99(4):785-93 PMID: 4860926
  8. Removal by heparin-MnCl2 of nonspecific rubella hemagglutinin serum inhibitor.
    Proc Soc Exp Biol Med. 1968 Feb;127(2):570-3 PMID: 5689482
  9. Physical and immunologic properties of rubella antigens.
    J Immunol. 1968 Apr;100(4):851-7 PMID: 5645224
  10. Serology of rubella. Virus neutralization, immunofluorescence in BHK21 cells, and hemagglutination inhibition.
    N Y State J Med. 1968 Jun 1;68(11):1355-62 PMID: 4870797
  11. An improved diluent for rubella hemagglutination and hemagglutination-inhibition tests.
    Appl Microbiol. 1968 May;16(5):691-4 PMID: 5659363
  12. The nonspecific inhibitors of rubella-virus hemagglutination.
    Proc Soc Exp Biol Med. 1968 Jun;128(2):577-81 PMID: 5663277
  13. A simple method for removal of rubella hemagglutination inhibitors from serum adaptable to finger-tip blood.
    Am J Epidemiol. 1968 Nov;88(3):301-4 PMID: 4972370
  14. Experience with a modified rubella hemagglutination inhibition antibody test.
    JAMA. 1969 Jan 6;207(1):89-93 PMID: 5818144
  15. Evaluation of serological techniques for titration of rubella antibody.
    Am J Public Health Nations Health. 1969 Feb;59(2):297-304 PMID: 4886108
  16. Analysis of the diluents used for rubella virus hemagglutination and hemagglutination-inhibition tests.
    Appl Microbiol. 1969 Aug;18(2):221-7 PMID: 5807157
  17. Rubella-virus hemagglutination-inhibition test.
    N Engl J Med. 1967 Mar 9;276(10):554-7 PMID: 6019765
Article Info
Journal
Applied microbiology
Abbr.
Appl Microbiol
ISSN
0003-6919
Published
1970-03-00
Pages
491-504
Language
English
Region
United States
NLM ID
7605802
PMCID
PMC376718
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]