Abstract
In a systematic approach, 37 duplicate samples of open system circuits (Bennett MA-1 ventilators) of patients in medical and surgical intensive care units were processed by direct and serial (APHA guidelines) dilutions. The paired difference test on 15 of the in-use circuitry solution samples indicated no difference between the direct and serial dilution methods (P less than 0.001). Seventy-seven additional respiratory therapy circuitry samples from similar intensive care patients were analyzed via a direct dilution method alone and processed microbiologically. The direct dilution procedure was a rapid and accurate means of evaluation of microbial contamination in the range of greater than or equal to 10 to less than or equal to 10(6) CFU/ml. High densities of organisms frequently were found. Sites of contamination included the proximal or patient end of the circuitry (heaviest), the nebulizer trap, and the distal or humidifier portions of the circuitry. The contaminants found were predominantly gram-negative nonfermenters: Acinetobacter calcoaceticus var. antitratus, Pseudomonas aeruginosa, Pseudomonas maltophilia, and Flavobacterium meningosepticum. Fermenters were Klebsiella pneumoniae, Proteus sp., Enterobacter cloacae, Citrobacter diversus, and Enterobacter agglomerans. Infrequently, gram-positive Streptococcus spp. and Staphylococcus spp. were noted.
MeSH Terms
Air Microbiology
Bacteria/isolation & purification
Humans
Intensive Care Units
Respiratory Therapy/standards
Ventilators, Mechanical/standards
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Malecka-Griggs B
Reinhardt D J
References (15)
15 references, click to expand
-
Simple methods of bacteriologic sampling of nebulization equipment.
Am Rev Respir Dis. 1966 Sep;94(3):450-3
PMID: 5331326
-
Changing pharyngeal bacterial flora of hospitalized patients. Emergence of gram-negative bacilli.
N Engl J Med. 1969 Nov 20;281(21):1137-40
PMID: 4899868
-
Nosocomial respiratory infections with gram-negative bacilli. The significance of colonization of the respiratory tract.
Ann Intern Med. 1972 Nov;77(5):701-6
PMID: 5081492
-
Bacterial contamination of aerosols.
Arch Intern Med. 1973 Jan;131(1):156-9
PMID: 4565025
-
Pneumonia in an intensive care unit. A 30-month experience.
Arch Intern Med. 1974 Jul;134(1):106-11
PMID: 4365670
-
Gram-negative water bacteria in hemodialysis systems.
Health Lab Sci. 1975 Oct;12(4):321-34
PMID: 1236620
-
Deaths from nosocomial infections: experience in a university hospital and a community hospital.
Am J Med. 1980 Feb;68(2):219-23
PMID: 7355892
-
Selective nonroutine microbial surveillance of in-use hospital nebulizers by aerosol entrapment and direct sampling analyses of solutions in reservoirs.
J Clin Microbiol. 1980 Aug;12(2):199-204
PMID: 6785304
-
Limulus amoebocyte lysate and direct sampling methods for surveillance of operating nebulizers.
Appl Environ Microbiol. 1981 Nov;42(5):850-5
PMID: 7032421
-
Identification of procedure-related nosocomial infections in high-risk patients.
Rev Infect Dis. 1981 Jul-Aug;3(4):701-7
PMID: 6951236
-
Contamination of mechanical ventilators with tubing changes every 24 or 48 hours.
N Engl J Med. 1982 Jun 24;306(25):1505-9
PMID: 7043269
-
Guideline for prevention of nosocomial pneumonia.
Infect Control. 1982 Jul-Aug;3(4):327-33
PMID: 6956560
-
Survival and dissemination of bacteria in nebulizers and incubators.
Am J Dis Child. 1967 Jul;114(1):13-20
PMID: 4952773
-
THE POTENTIAL ROLE OF INHALATION THERAPY EQUIPMENT IN NOSOCOMIAL PULMONARY INFECTION.
J Clin Invest. 1965 May;44:831-9
PMID: 14276140
-
Nebulization equipment. A potential source of infection in gram-negative pneumonias.
Am J Dis Child. 1966 Apr;111(4):357-60
PMID: 5906045