Home LiteratureArticle Details
PMID: 6569873 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, P.H.S.

Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.

Journal of clinical microbiology ·Vol. 20 ·No. 6 ·1984-12-00 ·Pages 1068-75

Boyce JM, Lytle LS, Walsh DA

Abstract

To determine whether methicillin-resistant (MR) Staphylococcus aureus from different geographic areas are detected reliably by various commercially available microdilution broth and disk elution systems, 73 such isolates obtained from hospitals in 13 cities were tested by a reference method (agar dilution) and by the Microscan, API 3600S, Autobac I, and MS-2 systems. Both Eugonic broth and Low Thymidine Eugonic broth were used in the evaluation of the Autobac I, and two versions of the MS-2 were used. The proportions of isolates categorized as MR by the various methods were: agar dilution method, 99%; Microscan, 100% (if the suggested cut-off of the manufacturer was used); API 3600S, 96%; Autobac I, 84 to 93%; and MS-2, 54 to 68%. With the MS-2 system, isolates from Jackson, Miss., were classified as susceptible to methicillin more often than were strains from other cities. With the Autobac I (Eugonic broth), only 55% of isolates from Houston, Tex., were classified as MR, whereas 89% of isolates from all other cities were correctly classified as MR. With the API 3600S, strains from some cities were categorized as nafcillin susceptible, whereas strains from other cities were classified as resistant to nafcillin. The results of this study suggest that future evaluations of antimicrobial susceptibility testing systems should include MR strains of S. aureus from several geographic areas.

MeSH Terms
Humans Methicillin/pharmacology Microbial Sensitivity Tests/methods Penicillin Resistance Staphylococcus aureus/drug effects,isolation & purification
Chemicals
Methicillin
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Boyce J M
Lytle L S
Walsh D A
References (48)
48 references, click to expand
  1. Evaluation of the Sceptor microdilution antibiotic susceptibility testing system: a collaborative investigation.
    J Clin Microbiol. 1981 Jan;13(1):184-94 PMID: 6780600
  2. Evaluation of the Sensititre system for quantitative antimicrobial drug susceptibility testing: a collaborative study.
    Antimicrob Agents Chemother. 1980 Mar;17(3):464-9 PMID: 7425606
  3. Comparison of sensititre dried microtitration trays with a standard agar method for determination of minimum inhibitory concentrations of antimicrobial agents.
    Antimicrob Agents Chemother. 1980 Dec;18(6):844-52 PMID: 6972192
  4. Two-hospital study of Staphylococcus aureus susceptibility to penicillin and ampicillin by Autobac I.
    Antimicrob Agents Chemother. 1980 Dec;18(6):922-5 PMID: 7235678
  5. The antimicrobial susceptibility test: a comparison of the results of four methods.
    J Appl Bacteriol. 1981 Jun;50(3):505-17 PMID: 7019183
  6. Examination of major disagreements in susceptibility test results by Autobac-1 and MS-2.
    Antimicrob Agents Chemother. 1981 Jul;20(1):115-9 PMID: 7283410
  7. Rapid determination of the susceptibility of bacteria to antibiotics with Sensititre plates and nitroblue tetrazolium.
    J Antimicrob Chemother. 1981 Nov;8(5):363-9 PMID: 7319978
  8. Laboratory evaluation of the Anderson Technical semiautomated susceptibility testing system.
    Antimicrob Agents Chemother. 1981 Dec;20(6):777-82 PMID: 7325643
  9. Reliability of the MS-2 system in detecting methicillin-resistant Staphylococcus aureus.
    J Clin Microbiol. 1982 Feb;15(2):220-5 PMID: 6917854
  10. Methicillin-resistant Staphylococcus aureus susceptibility testing with Abbott MS-2 system.
    Antimicrob Agents Chemother. 1982 Apr;21(4):676-7 PMID: 6919413
  11. Comparison of lyophilized and frozen microtiter systems for routine MIC testing in the clinical laboratory.
    Am J Clin Pathol. 1982 Aug;78(2):223-8 PMID: 7048941
  12. Evaluation of the MICUR system for quantitative antimicrobial susceptibility testing: a multiphasic comparison with reference methods.
    J Clin Microbiol. 1982 Jul;16(1):153-63 PMID: 7107853
  13. The emergence of methicillin-resistant Staphylococcus aureus infections in United States hospitals. Possible role of the house staff-patient transfer circuit.
    Ann Intern Med. 1982 Sep;97(3):297-308 PMID: 7114626
  14. Evaluation of the Titertek Multiskan for determining minimal inhibitory concentration endpoints.
    Antimicrob Agents Chemother. 1982 Jul;22(1):151-3 PMID: 7125627
  15. Interlaboratory performance of disk agar diffusion and dilution antimicrobial susceptibility tests, 1979-1981. A summary of the microbiology portion of the College of American Pathologists (CAP) surveys.
    Am J Clin Pathol. 1982 Oct;78(4 Suppl):651-8 PMID: 7137106
  16. Collaborative evaluation of the microbial profile system for quantitative antimicrobial susceptibility testing.
    J Clin Microbiol. 1983 Mar;17(3):436-44 PMID: 6841580
  17. Concurrent comparability of automated systems and commercially prepared microdilution trays for susceptibility testing.
    J Clin Microbiol. 1983 May;17(5):878-86 PMID: 6863508
  18. Successful use of broth microdilution in susceptibility tests for methicillin-resistant (heteroresistant) staphylococci.
    J Clin Microbiol. 1983 Nov;18(5):1084-91 PMID: 6643661
  19. Interlaboratory variation of antibiograms of methicillin-resistant and methicillin-susceptible Staphylococcus aureus strains with conventional and commercial testing systems.
    J Clin Microbiol. 1983 Nov;18(5):1226-36 PMID: 6605976
  20. Reevaluation of the ability of the standardized disk diffusion test to detect methicillin-resistant strains of Staphylococcus aureus.
    J Clin Microbiol. 1984 Jun;19(6):813-7 PMID: 6565707
  21. Antibiotic susceptibility testing by a standardized single disk method.
    Am J Clin Pathol. 1966 Apr;45(4):493-6 PMID: 5325707
  22. Serial dilution antibiotic sensitivity testing with the microtitrator system.
    Am J Clin Pathol. 1966 May;45(5):548-51 PMID: 5328466
  23. Application of microtitration techniques to bacteriostatic and bactericidal antibiotic susceptibility testing.
    J Lab Clin Med. 1968 Sep;72(3):511-6 PMID: 4877134
  24. Evaluation of an automatic diluting device for microbiological applications.
    Appl Microbiol. 1968 Sep;16(9):1414-6 PMID: 4970994
  25. Growing clinical significance of methcillin-resistant Staphylococcus aureus.
    Lancet. 1968 Oct 5;2(7571):741-4 PMID: 4175546
  26. Semiautomatic microtechnique for serial dilution-antibiotic sensitivity testing in the clinical laboratory.
    J Lab Clin Med. 1968 Oct;72(4):685-7 PMID: 4175675
  27. Tube dilution antimicrobial susceptibility testing: efficacy of a microtechnique applicable to diagnostic laboratories.
    Appl Microbiol. 1969 May;17(5):707-9 PMID: 4891721
  28. Detailed methodology and implementation of a semiautomated serial dilution microtechnique for antimicrobial susceptibility testing.
    Appl Microbiol. 1970 Jul;20(1):46-53 PMID: 4917462
  29. Modification of the microtiter technique for antimicrobial drug susceptibility testing by incorporation of indicators.
    Appl Microbiol. 1970 Sep;20(3):342-5 PMID: 5485717
  30. A microdilution method for antibiotic susceptibility testing: an evaluation.
    Am J Clin Pathol. 1970 Jun;53(6):880-5 PMID: 5504607
  31. Microdilution antibiotic susceptibility test: examination of certain variables.
    Appl Microbiol. 1973 Nov;26(5):658-65 PMID: 4202703
  32. Laboratory evaluation of a rapid, automatic susceptibility testing system: report of a collaborative study.
    Antimicrob Agents Chemother. 1975 Apr;7(4):466-80 PMID: 1147582
  33. Short-term storage of six penicillins and cephalothin in microdilution trays for antimicrobial susceptibility tests.
    Antimicrob Agents Chemother. 1976 Jul;10(1):83-8 PMID: 791089
  34. Evaluation of the performance parameters of a prediluted, quantitative antibiotic susceptibility test device.
    Antimicrob Agents Chemother. 1977 Feb;11(2):271-6 PMID: 848934
  35. Evaluation of the Autobac 1 susceptibility testing system in a clinical diagnostic laboratory.
    Antimicrob Agents Chemother. 1977 Apr;11(4):750-2 PMID: 856028
  36. In-use evaluation of a prediluted quantitative antibiotic susceptibility test device.
    Antimicrob Agents Chemother. 1977 Oct;12(4):470-3 PMID: 335959
  37. Laboratory evaluation of an automated antimicrobial susceptibility system.
    Am J Clin Pathol. 1977 Dec;68(6):769-777 PMID: 602916
  38. Evaluation of the micro-media system for quantitative antimicrobial drug susceptibility testing: a collaborative study.
    Antimicrob Agents Chemother. 1978 Jan;13(1):61-9 PMID: 626491
  39. Methicillin-resistant Staphylococcus aureus susceptibility testing by an automated system, Autobac I.
    Antimicrob Agents Chemother. 1978 May;13(5):837-41 PMID: 248270
  40. Determination of antibiotic sensitivities by the Sensititre system.
    J Clin Pathol. 1978 Jun;31(6):531-5 PMID: 670407
  41. An assessment of the Sensititre method for determining minimum inhibitory and bactericidal concentrations.
    J Clin Pathol. 1978 Jun;31(6):536-8 PMID: 670408
  42. Broth dilution minimum inhibitory concentrations: rationale for use of selected antimicrobial concentrations.
    J Clin Microbiol. 1979 May;9(5):589-95 PMID: 479358
  43. Australian evaluation of Autobac I with suggested interpretive and technical modifications.
    Antimicrob Agents Chemother. 1979 Sep;16(3):255-61 PMID: 389157
  44. Evaluation of a semiautomated micro-broth dilution system for determing minimum inhibitory concentrations of antimicrobics.
    Am J Clin Pathol. 1980 Mar;73(3):374-9 PMID: 6767390
  45. Evaluation of the sensititre microdilution antibiotic susceptibility system against recent clinical isolates: three-laboratory collaborative study.
    J Clin Microbiol. 1980 Apr;11(4):426-9 PMID: 7372803
  46. Comparison of drug sensitivity testing with microdilution quantitative minimum inhibitory concentration and the Autobac I system.
    J Clin Microbiol. 1980 May;11(5):465-9 PMID: 7381010
  47. Clinical evaluation of automated antibiotic susceptibility testing with the MS-2 system.
    J Clin Microbiol. 1980 Oct;12(4):527-32 PMID: 7419705
  48. Clinical laboratory evaluation of the Abbott MS-2 automated antimicrobial susceptibility testing system: report of a collaborative study.
    J Clin Microbiol. 1980 Sep;12(3):375-90 PMID: 6783678
Article Info
Journal
Journal of clinical microbiology
Abbr.
J Clin Microbiol
ISSN
0095-1137
Published
1984-12-00
Pages
1068-75
Language
English
Region
United States
NLM ID
7505564
PMCID
PMC271519
Subset
IM
Grants
NCRR NIH HHS · 5S07 RR05386 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]